_______________________________________________________________________________________________________________________________
Distance to flammable material
Behind the stove
Behind stove with
Corner
To the sides of the
To furniture
insulated flue pipe
arrangement
stove
17 cm
12 cm
30 cm
45 cm
100 cm
*with an insulated flue pipe
Bagside / behind / hinten
17 / *12
30
30
45
45
100
100
Please note: that the Aduro 1-1 must be installed on a floor with the adequate load-bearing capacity. If the existing
construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a load-
distributing plate).
If the wood burning stove is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the wood burning
stove, and 15 cm on each side.

3.2 Pipe connection

Aduro 1-1 leaves the factory with the flue outlet mounted on the top. If you
require the flue outlet on the back, remove the round circle from the rear cover at
the upper rear of the stove and then exchange the exhaust connector (located on
the top outlet above the stove) with the cover plate (that covers the rear outlet).
The top outlet is finished with the plate that lies in the ash drawer. Be aware that
the cover plate ensures the distance to the soapstone top on the 1-1SK model. It
is therefore important that the flanges turn upwards when being mounted (see
illustration).
A flue pipe with an internal diameter of 150 mm should be used for Aduro stoves.
3.3 Connection to a brick chimney
If the stove is being connected to a brick chimney, the rear outlet should be used, or a curved flue pipe via the top
outlet. After measurement, a hole is made in the chimney in which the pipe sleeve is placed and fireplace mortar is
used to seal it in place. The stove is placed in position and the flue pipe is put in place. A thin gasket is placed
between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude 5–10 cm into the pipe
sleeve, but must not block the opening in the chimney (see the illustration below).