Herunterladen Inhalt Inhalt Diese Seite drucken

Thecus N8900 Serie Bedienungsanleitung Seite 85

Vorschau ausblenden Andere Handbücher für N8900 Serie:
Inhaltsverzeichnis

Werbung

Die nachstehende Tabelle listet mö gliche RAID-Migrationsschemata auf:
Zu
Von
RAID 0
RAID
1
RAID
X
5
RAID 5
[RAID 1] HDD x 2 zu [RAID 5] HDD x 3
[RAID 1] HDD x 2 zu [RAID 5] HDD x 4
[RAID 1] HDD x 2 zu [RAID 5] HDD x 5
[RAID 1] HDD x 2 zu [RAID 5] HDD x 6
[RAID 1] HDD x 2 zu [RAID 5] HDD x 7
[RAID 1] HDD x 2 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 3 zu [RAID 5] HDD x 4
[RAID 1] HDD x 3 zu [RAID 5] HDD x 5
[RAID 1] HDD x 3 zu [RAID 5] HDD x 6
[RAID 1] HDD x 3 zu [RAID 5] HDD x 7
[RAID 1] HDD x 3 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 4 zu [RAID 5] HDD x 1
[RAID 1] HDD x 4 zu [RAID 5] HDD x 6
[RAID 1] HDD x 4 zu [RAID 5] HDD x 7
[RAID 1] HDD x 4 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 5 zu [RAID 5] HDD x 6
[RAID 1] HDD x 5 zu [RAID 5] HDD x 7
[RAID 1] HDD x 5 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 6 zu [RAID 5] HDD x 7
[RAID 1] HDD x 6 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 7 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 3 zu [RAID 5] HDD x 4
[RAID 5] HDD x 3 zu [RAID 5] HDD x 5
[RAID 5] HDD x 3 zu [RAID 5] HDD x 6
[RAID 5] HDD x 3 zu [RAID 5] HDD x 7
[RAID 5] HDD x 3 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 4 zu [RAID 5] HDD x 5
[RAID 5] HDD x 4 zu [RAID 5] HDD x 6
[RAID 5] HDD x 4 zu [RAID 5] HDD x 7
[RAID 5] HDD x 4 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 5 zu [RAID 5] HDD x 6
[RAID 5] HDD x 5 zu [RAID 5] HDD x 7
[RAID 5] HDD x 5 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 6 zu [RAID 5] HDD x 7
[RAID 5] HDD x 6 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 6] HDD x 7 zu [RAID 5] HDD x 8
......................................HDD x 16
85
RAID 6
[RAID 1] HDD x 2 zu [RAID 6] HDD x 4
[RAID 1] HDD x 2 zu [RAID 6] HDD x 5
[RAID 1] HDD x 2 zu [RAID 6] HDD x 6
[RAID 1] HDD x 2 zu [RAID 6] HDD x 7
[RAID 1] HDD x 2 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 3 zu [RAID 6] HDD x 4
[RAID 1] HDD x 3 zu [RAID 6] HDD x 5
[RAID 1] HDD x 3 zu [RAID 6] HDD x 6
[RAID 1] HDD x 3 zu [RAID 6] HDD x 7
[RAID 1] HDD x 3 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 4 zu [RAID 6] HDD x 5
[RAID 1] HDD x 4 zu [RAID 6] HDD x 6
[RAID 1] HDD x 4 zu [RAID 6] HDD x 7
[RAID 1] HDD x 4 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 5 zu [RAID 6] HDD x 6
[RAID 1] HDD x 5 zu [RAID 6] HDD x 7
[RAID 1] HDD x 6 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 6 zu [RAID 6] HDD x 7
[RAID 1] HDD x 6 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 1] HDD x 7 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 3 zu [RAID 5] HDD x 4
[RAID 5] HDD x 3 zu [RAID 6] HDD x 5
[RAID 5] HDD x 3 zu [RAID 6] HDD x 6
[RAID 5] HDD x 3 zu [RAID 6] HDD x 7
[RAID 5] HDD x 3 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 4 zu [RAID 6] HDD x 5
[RAID 5] HDD x 4 zu [RAID 6] HDD x 6
[RAID 5] HDD x 4 zu [RAID 6] HDD x 7
[RAID 5] HDD x 4 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 6 zu [RAID 6] HDD x 6
[RAID 5] HDD x 5 zu [RAID 6] HDD x 7
[RAID 5] HDD x 6 zu [RAID 5] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 6 zu [RAID 6] HDD x 7
[RAID 5] HDD x 6 zu [RAID 6] HDD x 8
......................................HDD x 16
[RAID 5] HDD x 7 zu [RAID 6] HDD x 8
......................................HDD x 16

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

N6850/n8850N12000 serieN7510N16000 serie n5550

Inhaltsverzeichnis