Herunterladen Inhalt Inhalt Diese Seite drucken

Calculation Of The Thermal Power - Nordica NORMA - S IDRO DSA Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NORMA - S IDRO DSA
With the system switched off, once a year carry out the following checks:
• Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your authorised installer. IT IS
STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY DEVICES.
• Check the thermal insulation of the filling pipe and the safety pipe.
• Make sure that the system is filled and under pressure, checking the water level in the expansion tank; also check that it is working
properly and check the efficiency of the safety pipe.

13. CALCULATION OF THE THERMAL POWER

There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is 30 kcal/h per m
an external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 38 W/m
Let's suppose one wishes to heat a room of 150 m
x 38 W/m
= 5700 W or 5,7 kW. As main heating, a 8 kW device is therefore sufficient.
3
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
Brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity
7197130s - IT-EN-DE-FR
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
Approximate combustion value
Unit
kcal/h
kg
3600
kg
1850
kg
4000
kg
4800
kg
7700
kg
6780
m
7800
3
L
8500
kW/h
860
.
3
Required quantity in relation to 1 kg of dry
kW
4.2
2.2
5.0
5.6
8.9
7.9
9.1
9.9
1.0
(for
3
3
wood
1,00
1,95
0,84
0,75
0,47
0,53
0,46
0,42
4,19
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis