Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; General Precautions; Installation Regulations - Nordica TERMOSOVRANA Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TERMOSOVRANA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. TECHNICAL DATA

Definition in accordance with EN 12815
Constructive system
Global thermal power in kW
Nominal thermal power in kW
Power given back to water in kW
Power given back to the room in kW
Hourly wood consumption in kg / h (wood with 20% humidity)
Efficiency in %
CO measured at 13% oxygen in %
Smoke outlet diameter in mm
Chimney height - dimension in mm
Fluid contents of the exchanger (H
Chimney draught in Pa (mm H
Boiler connections (Ø)
Automatic discharge pipe diameter (Ø)
Outer air inlet Ø in mm (minimum surface cm
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Optimal working temperature in °C
Max. working pressure in bar (expansion vessel Open - Closed)
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
(30 kcal/h x m
3
(#) 200 mm diameter can be used with flue of no less than 6 m.
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
(# #)
of the product is: favourable type of building (30 kcal/h x m
building (50 kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT: The power of the connected heating system must be proportional to the power transferred to the water by the thermoproduct;
a charge which is too low does not allow regular oven operation, while a charge which is too high prevents adequate radiator heating.

2. GENERAL PRECAUTIONS

La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well as
for the use of non-original spare parts. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A.
cannot be held responsible for lack of respect for such precautions.
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.

3. INSTALLATION REGULATIONS

Installation of the product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
18
O) in L (litres)
2
O)
2
)
2
)
3
).
3
(#)
(# #)
); less favourable type of building (40 kcal/h x m
3
TERMOSOVRANA - DSA
TERMOSOVRANA - DSA
1
16,6
13,5
9
4,5
3,9
81,2
0,12
130 S / P
5m – 220x220 Ø220
12
17 - 20 (1.7 - 2.0)
1 "F gas
½"M gas
200 ( 100 )
17
172
70 - 75
VA 1,5 bar - VEC 3 bar
217 x 172
257 x 250 x 395
330 x 300 x 410
Movable - flat
889
964
640
166
Chapter FIRE SAFETY
387
); unfavourable type of
3
7094211 - IT - EN - DE - FR

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dsa

Inhaltsverzeichnis