5. Remove the product from the USB power source when the display shows a full battery or when it has
already turned off. The device is fully charged and ready for use.
6. The current battery level is displayed during charging.
The position of a flashing LED indicates the current battery level during charging
(the battery is 75 % charged). The number of LEDs alight indicates the current
battery level of the internal battery. All four LEDs will stay on when the battery is
100% charged. The LED battery level display (3) turns off after about 20 seconds.
It takes about 14 hours to fully charge the battery at a maximum input current (see "Technical data").
The actual charging time required depends on the battery level and the charging current used.
If you only use the product occasionally, we recommend that you fully charge the internal battery
every three months in order to retain maximum capacity.
c) Charging a mobile device
Press the multifunction button
(4) to display the battery level of the power bank. Charge the
power bank before charging a mobile device if the battery level is insufficient.
1. Open the cover (1) by sliding both locking buttons inwards in the direction of the arrow.
2. Connect the micro USB connector to the micro USB port (6) on your mobile device.
3. Connect the USB-A connector on the micro USB cable to the USB port 1 (5) or the USB port 2 (7) on
the power bank. Refer to the technical data of the mobile device that you are going to charge and the
output power of the power bank. You can charge a second mobile device by connecting it to the second
USB-A port. An additional USB cable is required (not included with the product).
4. Press the multifunction button
to begin charging. The LEDs on the battery level display (3) light up
when charging begins. They indicate the remaining capacity of the power bank.
5. Monitor the charging process. Charging can be interrupted using the multifunction button
hold the multifunction button
for approximately 2 seconds. The charging process is interrupted.
6. Alternatively, you can also interrupt the charging process by disconnecting the micro USB cable from
one or both of the mobile devices.
If you disconnect one USB connection, you can re-establish the USB connection within
40 seconds to immediately resume charging the same mobile device or another mobile device.
The charging LEDs will stay on for 40 seconds after the connection is disconnected. After this time
has passed, this quick change is no longer possible. The multifunction button
again to restart the charging process.
7. The power bank switches to trickle charging the rechargeable battery. The amount of power charged is
equal to the battery's self-discharge.
8. Remove the micro USB cable from the product and the mobile device after charging is complete.
It is not possible to charge the power bank whilst using it to charge a mobile device.
d) Flashlight function
A built-in LED torch (2) enables you to use the product as a flashlight.
1. Press the multifunction button
(4) twice in succession to turn on the LED torch. The LED turns on.
2. Press the multifunction button
again after the LED torch turns on to turn on the warning flash. The
LED flashes.
3. Press the multifunction button
again to turn on the SOS function. The LED turns on and off to signal
SOS in Morse code.
4. Press the multifunction button
twice in succession to turn off the flashlight. The LED turns off.
e) Overload, overcharge and overcurrent protection
• The LED battery indicator (3) turns off in the event of an overload. The device turns off automatically
after a short period. Remove the connected device and reset the power bank by recharging it. Press the
multifunction button
(4) to resume charging.
• The LED battery indicator flashes quickly at 25 % in the event of a total discharge The torch function
doesn't work. Remove the connected device and recharge the product.
• In the event of an overcurrent (short circuit), the four LED charging indicators will flash quickly. Remove
the connected device or the power supply. Recharge the product. Press the multifunction button
use the product again.
f) Storage and transport
• Close the cover (1) when not using the product or when transporting it.
• To close the cover, slide both the locking buttons inwards in the direction of the arrow, then insert the
cover into the opening and release the locking buttons. The locking buttons must click firmly into place.
Ensure that the seal fits properly and that there is no dirt trapped inside.

MAINTENANCE AND CLEANING

Never use aggressive and abrasive detergents, rubbing alcohol or other chemical
solutions, as these could damage the housing or even impair the functioning of the
product.
• Disconnect the micro USB cable and connected mobile devices from the product before cleaning.
• Do not immerse the product in water.
• Clean all sealing surfaces of the cover (1).
• Under no circumstances should you service any of the components in the interior of the product,
therefore never open/dismantle it.
• A dry, soft and clean cloth is sufficient for cleaning. Do not press too hard on the housing as this can lead
to scratch marks.
• Dust can be easily removed using a soft and clean long-haired brush.
DISPOSAL
a) Product
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
b) Rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used rechargeable batteries; they
must not be disposed of in household waste!
Contaminated rechargeable batteries are labelled with this symbol to indicate that disposal in
the domestic waste is forbidden. The designations for the heavy metals involved are:
Cd = Cadmium, Hg = Mercury, Pb = Lead (name on rechargeable batteries, e.g. below the trash
icon on the left).
Used rechargeable batteries can be returned to collection points in your municipality, our stores
or wherever rechargeable batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Input voltage / current ....................................5 V/DC, max. 2 A
Output voltage/current 1 ................................5 V/DC, max. 1.5 A
Output voltage/current 2 ................................5 V/DC, max. 2.4 A
Internal rechargeable battery .........................Lithium-Ion (Li-Ion) 3.7 V / 18000 mAh
Charging time ................................................ approx. 14 h (complete charge with residual charge)
. Press and
Protection class .............................................IP65
LED colour temperature ................................6000 - 6500 K
Operating conditions ......................................-10 to +40 °C, 0 - 100 % RH
Storage conditions .........................................-25 to +60 °C, 0 - 100 % RH
Dimensions (W x H x D) ................................158 x 30 x 90 mm
Weight ...........................................................480 g
must be pressed
to
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2016 by Conrad Electronic SE
V2_0416_02-DS

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1406366

Inhaltsverzeichnis