To insert/replace the batteries proceed as follows:
Disconnect the device from the mains socket and remove all connected cables.
Remove the two rear screws from the battery compartment. Remove the lid carefully.
Insert two new button cells of the same type into the battery compartment, paying
attention to the correct polarity. The plus pole of both batteries should points
outwards.
Close the battery compartment and screw back in place.
Display
The display is divided into three parts in order to show several parameters simultaneously. The selection of the parameters for the
individual display areas is done with the keys 3, 2 and 9. The grid symbols on the keys indicate the display area.
Each time you press an individual key, the display is switched to the next parameter.
Key 3 switches the display area on the left top,
Key 2 switches the display area on the right top,
Key 9 shifts the display area on the bottom.
Presetting the tariff and alarm limit for the current and rated power
Some of the parameters in the display on the top right and on the bottom can be set individually. However, the parameters can only
be set one after the other. Make sure only the appropriate parameter is selected in the display. The setting will be completed, if no
button is pushed for about 10 seconds.
The measuring instrument has options for individually setting the electricity tariffs (cost/kWh) and alarm limits for the max. current
(A) or the max. electrical power. When the set current or power values are exceeded a signal is emitted.
Setting the electricity tariff "€cost/kWh":
Press the key ▼ (2) repeatedly, until "W" appears in the upper right display.
Press the key „● (9) repeatedly, until the display shows "COST/kWh €".
The "SET" key (8) activates the settings menu. The first digit flashes. If you press the key again, the decimal place will change.
With the keys ▲ (3) and ▼ (2), the value can be changed.
To complete the setting, press the key ● (9) or wait for approx. 10s. The setting is completed.
Setting the alarm limit for max. current and max. rated power:
Press the key ● (9) repeatedly, until the lower display shows "TOTAL kWh".
Press the key ▼ (2) repeatedly, until the display shows "OVERLOAD".
The „SET" key (8) activates the settings menu. The last set unit (W or A) flashes.
With the keys ▲ (3) and ▼ (2) the unit can be changed.
"W" corresponds to the effective power in Watt
"A" corresponds to the current in ampere.
The "SET" key (8) confirms the selection and switches to the next digit input. The first digit flashes.
If you press the key again, the decimal place will change.
With the keys ▲(3) and ▼(2), the value can be changed.
To complete the setting, press the key ● (9) or wait for approx. 10s. The setting is completed.
+
+
+
+