Special Functions
CMRR
(Common Mode Rejection Ratio)
DC voltage shares can occur at the
COM as well as at the voltage input
socket with reference to ground.
The Multimeter series UNITEST
Hexagon is equipped with a CMRR
mode.
Hereby undesirable DC voltage
shares are suppressed which
could cause digital jumps or off-
sets during voltage measure-
ments.
The CMRR mode for the UNITEST
Hexagon series is specified to >60
dB at 0...60 Hz in AC voltage ran-
ges and >120 dB at 0 Hz, 50 Hz and
60 Hz in DC voltage ranges.
64

7.9 Fiber Optic Technology

7.9.1 Example:
Carrying out the insertion loss
measurement in compliance with
IEC 874-1, method 6.
Fiber optic technology (only pos-
sible with accessory OPM110)
also refer to instruction manual
BEHAcom OPM-110.
General information to carry out
measurements in compliance with
IEC874-1.
IEC874-1 deals with plug connec-
tors for optical waveguides and
cables. It also contains how to
carry out reproducible measure-
ments of optical attenuation in
optical
waveguide
systems.
Methods 6 and 7 are of particular
importance. Method 7 is only valid
for short test paths whereby both
connection of an optical wavegui-
de system are directly accessible
within one room, e.g. patch cords,
pigtails. Method 6 has general vali-
dity and can always be carried out,
however requires a larger amount
of measurement cables and cou-
plings.