10 Additional features for flash units
1a, 1b
10
22
User manual // Strobe Wizard Plus / freemask transmitter
Camera settings:
If your camera supports these settings, use the following
settings for the Freemask application:
1. Speed of picture series to fastest setting.
2. Number of exposures to two.
This ensures the setting to highest picture frequency with
two succeeding exposures (depending on camera).
The transmitter will then trigger the flash group 1 (C1, C2,
and C3) for the set lighting and the flash group 2 (F1, F2,
and F3) for the mask lighting, during the two camera
exposures.
At present, all cameras are supported with picture series
speeds from 3 pictures per second to (in theory) 500
pictures per second.
The transmitter automatically defaults to one picture after
200 ms. This is not dependent on the actual number of
exposures. This ensures that the set lighting is always the
first exposure and the mask lighting the second exposure
when using the freemask application.
with built-in receiver
The buttons 1a and 1b allow further options for HENSEL
flash units with a built-in receiver. A single click on the
respective button reduces and increases the flash power
by 1/10 f-stop. Pressing button 1a for longer than 3
seconds switches the modeling light from FULL to OFF
and PROP, respectively.
Dependent on the working channel selected these options
are available selectively per working group (channel 1-3
selected) or these options go for all flash units in-
dependently of the selected channel (option 'All' selected).
The receiver is equipped with an interface socket 10 for
Hensel power packs.