Herunterladen Inhalt Inhalt Diese Seite drucken

Vacuum System Motor Filter Cleaning; Solution Filter Cleaning - Nilfisk-ALTO SCRUBTEC 545B Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SCRUBTEC 545B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH

VACUUM SYSTEM MOTOR FILTER CLEANING

1.
Drive the machine on a level floor.
2.
Turn the ignition key (80) to "0".
3.
Open the recovery tank.
4.
If necessary, drain the water from the tank in order to make the filter visible.
5.
Check that the pre-filter is clean. If necessary clean it with water and compressed air, then install it.
6.
Perform steps 1, 2 and 3 in the reverse order.

SOLUTION FILTER CLEANING

1.
Drive the machine on a level floor.
2.
Turn the ignition key (80) to "0".
3.
Close the solution tap (A, Fig. 7) under the machine, behind the right rear wheel. The valve (A) is closed when it is in the
position (B) and it is open when it is in the position (C).
4.
Remove the transparent cover (D), then remove the filter strainer (E). Clean and install them on the support (F).
NOTE
The filter strainer (E) must be correctly positioned on the housing (G) of the support (F).
5.
Open the valve (A).
G
E
22
INSTRUCTIONS FOR USE
F
E
D
SCRUBTEC 545B / 545BL / 553B / 553BL / BOOST 5 - 9097054000
Figure 7
05/2015
A
B
C
P100109
02/2007

Werbung