3.7
Step 7: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fi tted. Place a suitable container
under the cartridge to catch any leakages.
A Turn on the cold water supply and check the system carefully for
any leaks.
B Open the valve on your BRITA water dispenser and rinse through
until the fi ltered water runs clear and without any bubbles
(at least 2 litres).
4
Replacing the fi lter cartridge
The fi lter cartridge must be replaced when it runs out or at
latest 6 months after commissioning, irrespective of the level of
exhaustion of the fi lter system.
Read the Operating and Safety Information (chapter 9)
prior to exchange. After storage and transport below 0°C,
!
the product must be stored in the open original packaging
for at least 24 hours at the stated ambient temperatures
( chapter 7) for operation.
The fi lter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and by-passing
with direct water fl ow from the water inlet to the outlet is
possible.
Replacing the On Line P 1000 (see fi g. 7):
A Open the locking handle (3).
B Place a suitable container under the fl ush hose to catch the rinse
water. Activate the fl ush valve (5) and release pressure from the
system.
C Remove the exhausted fi lter cartridge (4) from the fi lter head (2) –
please be aware, the cartridge is fi rmly embedded so you can
give it a fi rm pull without worrying about breaking it.
D Insert the new fi lter cartridge (see chapter 3.5).
E Close the locking handle (3).
F Reset the BRITA cartridge exchange indicator (chapter 5).
10
ENGLISH
5
Resetting the BRITA electronic cartridge
exchange indicator
If the maximum time or volume is reached, the BRITA electronic
cartridge exchange indicator's LED will start blinking red (while the
BRITA water dispenser's lever is turned to the open position).
– then the fi lter cartridge should be changed (chapter 4).
– the BRITA electronic cartridge exchange indicator has to be
reset.
a) Take the BRITA electronic cartridge exchange indicator out of
the BRITA water dispenser's lever.
b) Take the battery out carefully.
c) Put it back into the cartridge exchange indicator (the battery
side marked with the + has to be on top) and press it fi rmly
until you see the red and blue light blink once on the other
side of the BRITA electronic cartridge exchange indicator.
This shows that the indicator has successfully been reset.
d) Afterwards, put the BRITA electronic cartridge exchange indi-
cator back into the BRITA water dispenser's lever. The side
with the battery has to face the BRITA logo on the lever.
6
Maintenance
Regularly check the fi lter system for leaks. Regularly check the
hoses for kinks. Bent hoses must be replaced.
Even though the product life time is 10 years, we recommend to
check it after 5 years after extraordinary wear and tear.
Prior to exchanging the fi lter system, read the Technical
!
Data (chapter 7) and the Operating and Safety Information
(chapter 9).
Regularly clean the outside of the fi lter system with a soft, damp
cloth.
Do not use any abrasive chemicals, cleaning solutions or
!
astringent cleaning agents.