OBJ_BUCH-1747-003.book Page 24 Tuesday, September 30, 2014 10:13 AM
24 | English
Removing/Replacing the Flat-fold Filter
(see figures J1–J2)
Replace a damaged flat-fold filter 30 immediately.
– Pull the locking latch 20 and open the filter cover 39.
– Grasp the flat-fold filter 30 by the fins, pull up and remove.
– When taking out the flat-fold filter 30, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 39 using a moist cloth.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
– Insert a new or the cleaned flat-fold filter 30; observe prop-
er and tight seating.
– Shut the filter cover 39 again (must be heard to engage).
Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure K)
Clean the level sensors 40 occasionally.
– Unlock the latches 15 and remove the vacuum lid 13.
– Clean the level sensors 40 with a soft cloth.
– Reattach the vacuum lid 13 again and lock the latches 15.

Correction of Malfunctions

Problem
The vacuum turbine does not start.
Vacuum turbine switches off.
Vacuum turbine does not restart after emptying
the container.
Vacuuming power decreases.
Dust escapes during vacuuming
The automatic shut-off (wet vacuuming) does
not respond.
1 609 92A 0XF | (30.9.14)
Storage (see figure L)
– Wind the mains cable around the cable holder 14.
– Insert the accessories into the holders provided: Vacuum
tubes 35 in holders 22, crevice nozzle 31 in holder 21,
floor nozzle 34 in holder 24.
– Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 27 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 11.
– For transport of the vacuum cleaner, screw the plug cap 2
onto the hose connection piece 3.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 18, actuate the castor brakes 17 by
pushing down.
Transport (see figure M)
– Carry the vacuum cleaner only by the carrying handle 10.
– Use the push handle 12 for moving the VAC around or pull-
ing it over edges or obstacles.
Corrective Measure
– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
40.
Mode selector switch 7 set to "Start/Stop automatic".
– Set mode selector switch 7 to the "vacuum" symbol and switch the power
tool connected to the socket outlet 5 on.
– Empty container 1.
– Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 sec-
onds.
– Clean level indicators 40 as well as the space between the level indicators 40
with a brush.
– Remove clogs from vacuum nozzle, vacuum tubes 35, vacuum hose 27 or
flat-fold filter 30.
– Replace disposal bag 29 or dust bag.
– Engage filter cover 39 properly.
– Mount vacuum cleaner lid 13 properly and lock latches 15.
– Replace flat-fold filter 30.
– Check proper installation of the flat-fold filter 30.
– Replace flat-fold filter 30.
– Clean level indicators 40 as well as the space between the level indicators 40
with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
– Monitor the level continuously.