Soft Menus
Parameters::Device Manager::Soft Menus
PNO
Parameter Descriptions
0908
Control Screen Mode
Defines the operation of the Control Screen
0
DISABLED
1
AUTO
2
CUSTOM
When set to DISABLED, the Control Screen menu is hidden.
When set to AUTO, the contents of the Control Screen menu depends on the sequencing mode of the drive, (local, remote or
communications).
When set to CUSTOM, the contents of the Control Screen may be defined by writing parameter numbers to the elements of the 1352
Control Screen array. Note that the contents of the 1352 Control Screen array are not saved in non-volatile memory, so the values
need to be initialised following a power-on reset.
1352
Control Screen
An array of PNOs that identifies the parameters to be shown in the Control Screen. The contents of this screen are set automatically
by the AC30 firmware when the control mode is changed.
1188
Favourites
An array of PNOs that identifies the parameters to be shown in the Favourites menu
1311
Setup
An array of PNOs that identifies the parameters to be shown in the Setup menu
1270
Monitor
An array of PNOs that identifies the parameters to be shown in the Monitor menu
Functional Description
The Soft Menus group of parameters are used to populate the associated menus depending on the associated application, (Control Screen,
Setup and Monitor) or the requirements of the location, (Favourites). The contents of the Setup and Monitor menus may only be set by the
application itself. The contents of the Favourites menu may be set by writing to the parameters in the Favourites array. Alternatively parameters
may be added to or removed from the Favourites menu by use of the GKP. Navigate to the parameter of interest and hold the OK key until the
attributes screen is shown. If the parameter is not already in the Favourites menu a pressing the Soft Right key adds the parameter to Favourites.
This operation is indicated by the icon
menu then press OK until the parameter attributes are shown. Remove the parameter from Favourites by pressing the Soft Right key. This
operation is indicated by the icon
AC30V series Variable Speed Drive
. Similarly, to remove a parameter from Favourites, navigate to the parameter in the Favourites
.