Replacing the G-LCD and B-LCD panels
With the top cabinet removed
(1) Disconnect the LCD flat cable from the output PWB connector.
(2) Remove the lock screws "b" and "c". Detach the R/B adjusting plate or the G adjusting plate together with the LCD
panel.
(3) Separate the LCD panel from the adjusting plate.
(4) Mount a new LCD panel in the reverse order of the above steps (1), (2) and (3).
~ Readjust the convergence and focus. Note that the G LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
SIDE VIEW
B-LCD
TOP VIEW
FRONT
Lock
screws "b"
2
2
Lock
screws "c"
B adjusting plate
3
B-LCD panel
mounting screws
Lock screws "c"
2
R-LCD
G-LCD
B-LCD
Z
2
X
Lock screws "c"
θY
SIDE VIEW
24
X
θY
Z
~
G adjusting plate
G-LCD
X
θZ
Y
G-LCD panel