Herunterladen Inhalt Inhalt Diese Seite drucken

Shutdown; Troubleshooting - STIEBEL ELTRON SOKI 7 E plus Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTALLATION

SHUTDOwN

9. Shutdown
Draining the system
The gravity brake is integrated inside the ball valve above the
pump and has an opening pressure of 20 hPa.
f Switch OFF the solar control unit and prevent it being
f
restarted.
WARNING Burns
The heat transfer medium expelled can be very hot.
f Position and secure the heat-resistant contain-
f
er in such a way that there is no risk for peo-
ple nearby when the solar thermal system is
drained.
f Open the gravity brake by moving the handle of the ball
f
valve to the 45° position.
In this position, the ball valve is half closed. The heat transfer
medium flows in both directions.
f Vent the system at the highest point (above the
f
collectors).
f Connect a heat-resistant hose to the lowest drain valve in
f
the solar thermal system. Ensure that the solar medium is
collected in a heat-resistant container.
f Open the drain valve at the lowest point of the system.
f
SOKI 7 E plus | SOKI E trend

10. Troubleshooting

Pump
Operating state
LED
Illumi-
The pump is running ac-
nates
cording to its setting.
green
Rapidly
The pump runs in the
flashes
venting function for
green
10 minutes. The required
output must then be set.
Illumi-
The pump is speed-con-
nates
trolled via a Pwm signal.
orange
Flashes
The pump is ready for op-
red/
eration but is not running.
green
The pump automatically
starts up again as soon
as the fault is no longer
present.
Flashes
The pump is blocked and
red
at a standstill.
Flashes
The pump is at a standstill. The pump is not
orange
LED off
No power supply to the
PCB.
If you cannot remedy the fault, call our service department. To
facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
000000-0000-000000
Cause
Remedy
Standard mode
-
Standard mode
-
Standard mode
-
Undervoltage
Check the power
(U < 160 V) or
supply. Ensure
overvoltage
that 195 V < U <
(U > 253 V)
253 V.
The motor tem-
Check the tem-
perature is too
perature of the
high.
heat transfer
medium and the
ambient temper-
ature.
The pump does
Replace the
not automatically
pump.
start up again.
Replace the
running.
pump.
The pump is not
Check the cables.
connected to the
power supply.
The LED is faulty. Check whether
the pump is run-
ning.
The PCB is faulty. Replace the
pump.
Made in Germany