Cleaning of the impeller (U5 and U6)
To clean the impeller, and in the event of an
obstacle or blockage, the foot strainer must be
levered off. After this, take out the screws on the
underside of the pump and remove the cover.
The impeller can now be cleaned.
CAUTION!
Worn impellers can have sharp edges.
If the pump performance decreases, the impel-
ler must be checked for wear and replaced by
the manufacturer if necessary.
Tightening torque M
for M 5 M
= 5 Nm
A
for Amtec 3,5 M
= 1 Nm
A
for Amtec 5,0 M
= 2 Nm
A
QUICK TIPS FOR

REMEDYING FAULTS

Pump does not work
• Check mains current (do not use a pin gauge)
• Fuse faulty = may be too weak (please refer to
Electrical Connection)
• Mains supply cable damaged = repair to be
carried out by manufacturer only
Pump runs but does not pump
• Empty the pressure pipe or hose to allow the
non-return valve to open and the air to escape
from the pump housing, it may be necessary
to carry out a ventilation drilling
Impeller blocked
• Solids and fibrous matter have become lod-
ged in the pump housing = clean
Decreased pumping performance
• Foot strainer obstructed = clean
• Pressure pipe obstructed = clean
• Rotor worn out = repair to be carried out by
the manufacturer
• Wrong direction of rotation (for a three-pha-
se current) = ask a qualified electrician to
change 2 phases of the supply line
for A2 screw materials
A
ENGLISH
JUNG PUMPEN GmbH - Industriestr. 4-6
33803 Steinhagen, Germany
401.13.1612
EN 12050-2:2001
Lifting plant for faecal-free wastewater DN 32
U3 K (JP00205/2)
U3 K spez. (JP09562/2)
U3 KS (JP00206/2)
U3 K spez. (JP44255)
U3 KS (JP09808/2)
U3 KS spez. (JP09563/2)
U3 KS spez. (JP45195)
Collecting and automatically lifting faecal-free
waste water above the backflow level in buildings
and sites
REACTION TO FIRE
WATERTIGHTNESS
EFFECTIVENESS (LIFTING EFFECT
- Pumping of solids
- Pipe connections
- Ventilation
- Minimum flow velocity
- Minimum free passage of the plant
- Minimum useful volume
MECHANICAL RESISTANCE
- Load bearing capacity and structural
stability of collection tank for use
- Structural stability of collection tank
for use inside buildings
NOISE LEVEL
DURABILITY
- of structural stability
- of lifting effectiveness
- of mechanical resistance
DANGEROUS SUBSTANCES
0197
13
U5 K (JP09386/0)
U5 KS (JP09387/0)
U5 KS (JP09417/0)
U6 K E (JP00226/2)
U6 K D (JP00228/3)
U6 K ES (JP00227/2)
U6 K ES (JP09260/2)
U6 K DS (JP00229/3)
U6 K DS (JP09261/3)
NPD
Pass
Pass
Pass
NPD
Pass
Pass
NPD
NPD
NPD
≤ 70 dB(A)
NPD
Pass
NPD
NPD
15 15