Herunterladen Inhalt Inhalt Diese Seite drucken

View Main - Monacor WALL-05DT Bedienungsanleitung

Aktiver lautsprecher für dante-netzwerke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.3.2 View MAIN (fig . 13)
[1] Buttons to switch over the view (change of view only possible at
the access level "Administrator")
[2] UNIT CONNECTION – connection status
green = connected
red
= not connected
[3] Name of unit; unit can be renamed
[4] PC PRESET
"SAVE" the current settings as presets on the computer (like
menu item "File Save") and "LOAD" the presets from the com-
puter (like menu item "File Open")
[5] SPEAKER PRESET
"SAVE" the current settings as presets in the speaker and "LOAD"
the presets from the speaker
Select the storage location in the list field and enter a name in
the upper field .
Note: To allow selection of a preset from the group control, save the preset
to one of the storage locations 10 – 19 .
[6] INPUT CONTROL for setting the gain (volume) for the inputs, level
indicators next to the control, input /display fields as a numeric
input facility beneath the control
[7] Level indicator MASTER LEVEL for the outputs LF (bass speaker)
and HF (tweeter)
[8] LINK switch (for controlling the two input channels together)
Channel IN-B will adopt the settings of channel IN-A .
48
[9] MUTE switch for muting the corresponding input
[10] List field to select the unit of measurement for the DELAY value
[11]: time or distance (for automatic calculation of the delay)
[11] Input /display field DELAY for setting the signal delay of the input
signals (e . g . to compensate differences in sound delay due to
different distances of individual speakers to the listening position)
Alternatively, use the sliding control to set the signal delay .
[12] List field to select the filter type for the high pass filter LOW CUT
with the following options:
Indication
But 6dB
Bes 6dB
But 12dB
Bes 12dB
L-R 12dB
But 18dB
Bes 18dB
But 24dB
Bes 24dB
L-R 24dB
[13] High pass filter LOW CUT: Input /display field for the cut-off
frequency (enter values in Hz, "Off" < 20Hz)
Alternatively, use the sliding control to set the frequency .
Filter type
Slope
Butterworth
6 dB/octave
Bessel
6 dB/octave
Butterworth
12 dB/octave
Bessel
12 dB/octave
Linkwitz-Riley
12 dB/octave
Butterworth
18 dB/octave
Bessel
18 dB/octave
Butterworth
24 dB/octave
Bessel
24 dB/octave
Linkwitz-Riley
24 dB/octave

Werbung

Inhaltsverzeichnis
loading