Herunterladen Inhalt Inhalt Diese Seite drucken

Managing Access Rights; Entering Passwords; Changing Passwords; Changing Access Rights - Monacor WALL-05DT Bedienungsanleitung

Aktiver lautsprecher für dante-netzwerke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.4 Managing access rights

7.4.1 Entering passwords

When the power supply is switched on, the access level "User" will
always be selected (
"Administrator", enter the corresponding password via the menu
item "Hardware Enter Password" .
To return to the "User" level during operation, enter the password
for the "User" level via the same menu item .

7.4.2 Changing passwords

To change the password of the current access level, call up the menu
item "Hardware Configure Change Password" . Enter the current
password first, then enter the new password and enter the new pass-
word again to confirm . Always make sure to remember the new
password!

7.4.3 Changing access rights

The access rights for the lower access levels can be defined via the
menu branch "Hardware Configure Global Access Rights" . The
table (fig . 16) shows the options and presets for the individual levels .

7.5 Locked State

To go to the lowest access level "Locked State", call up the menu
item "Hardware Lock Unit" . A message will appear pointing out
that you have to enter the correct password of a higher level before
you are able to exit the present level . Confirm this message with OK .
54
 chapter 6 .1) . To go to the higher access level

7.6 Standby

To set the unit to "Standby", call up the menu item "Hardware
Go to Standby" . To return to normal operation, call up the menu
item "Hardware Exit Standby" (compare chapter 7 .2) .

7.6.1 Automatic standby

When the speaker has not received any input signal for a while, it can
automatically be set to standby . Enter the desired time in minutes via
the menu item "Hardware Configure Auto Power Down" .
To deactivate this automatic feature, enter the value "0" .

7.7 Defining the settings to be used after switching on

To define the settings to be used when the unit is switched on, call up
the menu item "Hardware Configure Power On Preset" .
In the list field of the window displayed, select the preset to be
loaded automatically whenever the unit is switched on or select the
option "Last Setting" so that the unit will always start with the settings
of its previous operation before it was switched off .

7.8 Saving / Loading all presets

To save all presets of the unit to the computer, call up the menu item
"File Backup Presets" and select the storage location (folder) .
To load presets that have been saved, call up the menu item
"File Restore Presets" .

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis