6. Press the ALARM button twice to change to the setting mode of alarm 2.
7. Keep the ALARM button pressed until the hour digits flash.
8. Press the UP button or DOWN, button to change the hour setting. Press the ALARM
button to confirm the setting. The minute digits flash.
9. Press the UP button or the DOWN button to change the minute setting. Press the ALARM
button to confirm the setting. Alarm repeat flashes.
10. Press the UP button or the DOWN button to change the alarm repeat. Press the ALARM
button to confirm the setting. You now exit the setting mode.
You can choose between daily repetition (EVERY DAY), daily repetition excluding
Sunday (EX SUN) or excluding the entire weekend (EX SAT SUN). A set alarm is
then either repeated daily or remains silent on Sunday. Saturday and Sunday are
free of alarms in the third possible setting.
Operation
a) Back-lighting of the display
1. Press the SNOOZE/LIGHT button (4) or SNOOZE button (6) to light up the LCD for approx.
10 seconds.
b) Change displays
You can change the display of time, date and temperature manually. The normal display
shows the time.
1. Press the SNOOZE/LIGHT button or SNOOZE button once to display the month and day of
the current date on the LCD display.
2. Press the SNOOZE/LIGHT button or SNOOZE button twice to display the temperature on
the LCD.
3. Press the SNOOZE/LIGHT button or the SNOOZE button three times to return to the time
display.
If no buttons are pressed for approx. 10 seconds, the digital alarm clock returns
to the time display.
The digital alarm clock has an automatic cyclic display. The time, date and temperature are
displayed one after the other for a few seconds in an endless loop.
1. Briefly press the MODE button (7) once to switch on the automatic cyclic display. The
digital alarm clock outputs two short tones to confirm successful changeover.
2. The time is displayed for approx. 4 seconds, followed by the date and finally the
temperature display appears before this endless loop starts at the beginning again.
3. Briefly press the MODE button once to change to manual display. The digital alarm clock
outputs a short tone to confirm successful changeover.
c) Changing to 12/24 hour mode
Option 1
1. Press the UP button (8) when the time is shown on the LCD of the digital alarm clock to
change between the display of the time in 12 or 24 hour mode.
Option 2
1. Press the ALARM button (11) to access alarm mode.
2. Press the UP button when the alarm time is shown on the LCD of the digital alarm clock
to change between the display of the time in 12 or 24 hour mode.
d) Selecting the unit of measurement to display the temperature
1. Press the C/F button (10) when the temperature is shown on the LCD of the digital
alarm clock to change the unit of measurement of the temperature display. Celsius or
Fahrenheit is possible (°C, °F).
e) To end alarm or alarm signal, snooze function
Both alarms can be activated or deactivated when the alarm signal has not been triggered.
1. Press the ALARM button (11) once to access the setting mode of alarm time 1. Press
twice to change to the setting mode of alarm 2. The alarms can be activated/deactivated
in the same way in both cases.
2. Press the MODE button (7) twice to activate alarm time 1 only. The
3. Press the MODE button twice to activate alarm time 2 only. The
4. Press the MODE button three times to activate both alarm times (1 and 2). The
symbols are activated.
5. Press the MODE button four times to deactivate both alarm times (1 and 2). Both symbols
disappear and both alarms are deactivated.
If the crescendo wake-up signal for the set wake-up time is triggered, you can end the alarm
or switch on the snooze function.
1. Press the SNOOZE/LIGHT button (4) or SNOOZE button (6) to switch on the snooze
function. The alarm is interrupted for 5 minutes before it sounds again.
2. Press any other button to end the alarm.
3. Press the MODE button (7) to end the snooze function.

Maintenance and cleaning

• The product does not require maintenance except for occasional cleaning. For cleaning,
use a soft, anti-static and lint-free cloth.
• Do not use abrasive or chemical cleaning agents.
• Do not immerse the product in water.
Disposal
a) Product
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.

Technical data

Power supply ........................................... 3 x 1.5 V/DC batteries, type AAA/Micro
Battery service life.................................. approx. 4 months
Temperature display range ................... -10 to +60 °C
Operating conditions .............................. 0 to +50 °C, 20 - 90 % RH
Storage conditions.................................. 0 to +50 °C, 20 - 90 % RH
Dimensions (W x H x D).......................... 140 x 90 x 37 mm
Weight ....................................................... 154 g (without batteries)
symbol is displayed.
symbol is displayed.
2
1
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately
from the product.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate
that disposal in the domestic waste is forbidden. The designations for the heavy
metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on
(rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.