4.2
If the lamp cannot be turned on as a result of over-heating, you need to wait to light up again until the
lamp has cooled and the screen displays
successfully, the screen will be recovered. During the waiting period, the ON indicator on the panel will
be ON, indicating that the ballast is in the ON phase at present. If the lamp cannot be turned on success-
fully after a while, the ballast will alarm.
5. Default Settings
5.1 Electronic ballast:
Program will be Bypass, Power will be 600W, Disable Sun Function.
5.2 Remote control (including battery replacement):
Program will be Bypass, Power will be 600W, and Clock will be 12:00, Disable Sun Function
- The output power cannot be adjusted to exceed 110% of the rated power of the lamp for safety
reasons. For example, when a 400W lamp is used, the output power of the ballast cannot exceed
440W; otherwise, the lamp will be damaged.
- When the ballast operates in the Timer mode, the Start Time and Stop Time will not be maintained
in the following cases, but the Program parameters will be maintained. The default power-up time
of the ballast is the new Start Time. Then the RESET indicator will flash to remind you to reset the
Start Time.
- When the duration of power failure exceeds 5 hours and the ballast is
powered up again.
- When the duration of power failure exceeds 5 hours, power failure occurs again
within 1 hour after
being powered up again, and the ballast is powered up again regardless of the
duration of the second power failure.
grow in AG | Wallenroder Str. 7-9 | 13435 Berlin - Germany
www.gib-lighting.de
in sequence. When the lamp is turned on again
WARNINGS
EN