5.0

Installation

Note: The safety instructions on page 4 must be observed.
Installe the wind-/rain-control unit WRZ 40M-4G in a dry
environment.
Installe the vent switches in a position which can be easily
seen and accessed.

5.1 Installation process

► First open the wind-/rain-control unit and remove the circuit
board with control electronics from the plastic housing.
For this purpose loosen the 4 fixing screws on the circuit board.
► Break out cable entries on the plastic housing.
Observe the starting points for the screwdriver to the
predetermined breaking points according to image guidance
► Secure the plastic housing with suitable plugs and screws on
the wall
► Reinstall the circuit board with control electronics.
Fig.: Illustrated instructions break out cable entries on the
plastic housing
235
Fig.: Dimensions mounting holes for mounting an the wall
01/13424999503
Wind-/Rain-control unit WRZ 40M-4G
fixing screws
Grundplatine
circuit board
Fig.: WRZ 40M-4G with circuit board
starting points for the screwdriver
11