TECHNICAL DATA ADC C440
(All measurements RMS unwtd, 20 Hz... 20 kHz, 48 kHz internal sample rate,
referred to digital full scale and +20 dBu analog input level as not otherwise noted)
SYNC
External Inputs:
Sensitivity:
Input Formats:
Lock Range:
Internal Clocks:
Sync Source Indicators:
Clock Indicators:
Jitter:
Format Indicators:
ADC
Analog Inputs:
CMRR (@15 kHz):
Input Sensitivity:
Level Meter:
Crosstalk (@ 15 kHz):
Frequency Range (-1 dB):
THD+N (@ Fs -1 dB):
Dynamic Range:
Output Word Lenght:
Digital Output Format:
Digital Outputs:
General
Supply Voltage:
Case:
Front and Back:
Dimensions:
1 x BNC, unbalanced, impedance 75 ohms / 10 kOhms
200 mV at Tnom/2
WCLK
28 ... 108 kHz
44.1, 48, 96 kHz
WCLK, INT
Lock, 44.1, 48, 96 kHz, Error
< 1 nS
CON, PRO
2 x XLR, electronically balanced, Impedance 5 kOhms
> 60 dB
+2 dBu ... +25 dBu
2 x 4 LEDs, -30, -8, -2, 0 dBfs
< -110 dB
10 Hz ... 70 kHz
- 109 dB
119 dB (A-wtd)
24 bit
AES/EBU, S/P-DIF, 24 Bit, 28 ... 108 kHz
1 x XLR male, transformer balanced, impedance110 ohms
Output voltage > 3.5 Vss
1 x Cinch, unbalanced, impedance 75 ohms
Output voltage > 1 Vss
8 ... 12 V AC or DC, 500 mA
Stainless Steel
Stainless Steel
129 x 42 x 170 mm (WxHxD)
13