LEVEL METER
The level meter consists of two 4-segment
LED displays for both left and right channel.
Meter range is from -30 ... 0 dBFs whereas 0
dBFs means full scale of the A/D converter.
Dynamic law of the meter corresponds to DIN
PPM (Peak Program Meter) specifications.
Risetime for full scale is 2 msec while the
release time is 1.5 sec for -20 dB signal
decrease.
THE A/D CONVERTER
The converter of the A/D part is as PCM
converter of latest technology. It offers a 24 bit
wide digital signal with up to 192 kHz sample-
rate. The achievable dynamic rage exceeds
119 dB with THD+n at –109 dB.
THE DIGITAL OUTPUTS
ADC C440 offers two outputs, balanced and
coaxial. The data format (professional or con-
sumer) is identical on both outputs, regardless
of their physical or electrical standard. The
outputs are situated on the rear panel.
THE OPERATION
-
The balanced output is equipped with an
XLR type connector, transformer balan-
ced, impedance 110 ohms according to
AES 3/11 standard.
Output voltage is > 4 Vss.
The coaxial output is equipped with a
-
Cinch connector, unbalanced, impedance
75 ohms, according to IEC 958.
As the output voltage is 1 Vss, it also suits
for AES-id applications.
THE DIGITAL OUTPUT FORMAT
The digital output format (professional or con-
sumer) is selected by the "FORMAT" button.
The frequency information entries are proces-
sed correctly in professional mode. In consu-
mer mode the entries are processed as far as
possible (Fs > 48 kHz is not provided in consu-
mer mode).
HINT:
In consumer mode, SCMS information (copy
protection) is handled as follows:
-
Byte 0, Bit 2 = 1 = copy permitted /
copyright not asserted.
-
Byte 1, Bit 7 = 0 = original / pre-recorded
data.