Herunterladen Inhalt Inhalt Diese Seite drucken

Control Panel; Switching Off; Operating Possibilities; External Triggering - HEYLO Base Classic Bedienungsanleitung

Thermofogger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.1 Control panel

TIMER-LED, red
READY-LED, green
DMX IN-LED, yellow
MODE
UP/DOWN
ENTER

5.2 Switching off

Press the Mode button
The device will automatically switch off after 15 seconds.
A red point appears in the corner at the bottom right.
You can also switch off the device within 15 seconds by pressing the Enter button.
When switching off the DMX panel, the machine will automatically switch off after 15 seconds.
Please note that the Mode button
It must be pressed shortly. If the Mode button is pressed and held down for more than two seconds,
the device will change to the Timer mode.

6. Operating possibilities

6.1 External triggering

It is possible to trigger the fog generator externally via the XLR sockets.
As a rule: DMX has priority. That means: once the device is triggered via DMX 512, the values set by
means of DMX have priority over analog triggering of:
0-10V (+) DC
Optional cable remote control
Radio-controlled remote-control

6.2 Operation via DMX

Connect the fog generator to a DMX panel. To do so, use the 5-pole XLR socket on the back side of
the device. Once the device receives a correct DMX signal, the yellow DMX LED will illuminate.
until "off" appears in the display:
is not suitable for scrolling through the menu items.