Use
Preparations
•
The slider can only be moved once the locking screw (4)
has been undone.
•
Clean the measuring scale and all measuring surfaces.
•
Make sure that the display and all function buttons are
in working order.
Measuring
1. Undo the locking screw (4).
2. Turn the caliper on by pressing [ ON/OFF ].
3. Press [ mm/inch ] to select metric or imperial display.
4. Carry out the measurement.
5. Zero the caliper by pressing the [ ZERO ] button.
6. Press [ ON/OFF ] to turn the caliper off after
a completed measurement. Automatic shut-off after
20−30 minutes.
A. Outside measurement
C. Depth/height
measurement
B. Inside measurement
D. Step measurement
4