Herunterladen Inhalt Inhalt Diese Seite drucken

Internal Fuses And Configuration - IC Audio AMP 120 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Internal fuses and configuration

9.1 Internal extra-low voltage fuse
If there seems to be no supply voltage in a device, the rear side mains fuse and the internal extra-
low voltage fuse have to be checked first – see photos below. Of course only fuses with identical
value may be used.
The internal extra-low voltage fuses have the following specifications:
AMP 120
15 A, 6.3x32 mm
AMP 240
20 A, 6.3x32 mm
AMP 480
40 A, 10 x 38 mm
Internal fuse
AMP 240
Internal fuse
AMP 480
9.2 Jumper for determining input sensitivity
100mV
500mV
1V
All amplifiers AMP-series can be set up for 3 different values of input sensitivity by jumper SW401:
100 mV, 500 mV and 1 V.
Factory setting is 500 mV.
AMP 120/240/480
SW401
11
JP1
SW403
SW404
Lower printed circuit board
EN
Internal fuse
AMP 120
JP2
ic audio

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Amp 240Amp 480

Inhaltsverzeichnis