9. Internal fuses and configuration

9.1 Internal extra-low voltage fuse
If there seems to be no supply voltage in a device, the rear side mains fuse and the internal extra-
low voltage fuse have to be checked first – see photo below. Of course only fuses with identical
value may be used.
The internal extra-low voltage fuses are fitted with fuse links 5x20 mm 15 Amperes.
Internal fuses
AMP 4x120
9.2 Jumpers for selecting input sensitivity
By means of the jumpers SW301/302/401/402, the AMP 4x120 can be set up for 3 different input
sensitivities: 100 Millivolts, 500 Millivolts and 1 Volt. Please find jumper position by pcb-imprint.
Factory setting is 500 mV.