Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first time. Adhere to
the safety information for the correct and safe use of the unit.
Intended use
The Proficlear - Screendrive Module 2, in the following text termed unit, is intended to be used for the automatic cleaning
of the Screenex coarse dirt separator in the OASE Proficlear module M2 at a minimum water temperature of +8°C. Ensure
that the safety transformer is only operated at ambient temperatures of -10°C to +40°C.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void
CE Manufacturer's Declaration
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage directive
(73/23/EEC). The following harmonised standards apply: EN 60335-1, EN 61558-1, EN 61558-2-6, EN 55014-1,
EN 55014-2, EN 61000-3-2, EN 61000-3-3
Signature:
Safety information
OASE has manufactured this unit according to the highest quality standards and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accordance
with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognise
possible danger or who are not familar with these operating instructions, are not permitted to use this unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when passing the unit
on to a new owner. Ensure that all work with this unit is only carried out in accordance with these instructions.
The combination of water and electricity can imply a high risk to life and limb, if the unit is incorrectly connected or
inappropriately handled.
Attention! Danger of electric shock. Ensure that the cable connection points and their surroundings are dry.
The transformer and the cables contained in our scope of delivery are not submersible, but are only rain and splash-proof.
Do not route or fit under water.Protect the plug connection from moisture. Ensure that the safety transformer is located
at a minimum spacing from the pond edge of 2 m (in Germany) and 2.5 m in Switzerland. Protect the connection cable
when burying to avoid damage. Only use cables approved for outside use. Ensure that the power connection cable cross
section is not smaller than that of the rubber hoses with the identification H05RN-F. Extension cables must meet DIN VDE
0620. Unwind cables prior to use. Electrical installations at garden ponds and swimming pools must meet the national
and international regulations valid for installers. Compare the electrical data of the supply with those on the unit type plate.
This data must agree. Never operate the unit if the cable or housing are defective! Disconnect the power! Do not carry or
pull the unit by the connection cable.
Only use the unit with the attendant safety transformer contained in our scope of delivery. Never open the unit housing
or its attendant components, unless this is explicitly mentioned in the operating instructions. Always disconnect the power
supply of all units located in water and of this unit prior to performing work on the unit! For your own safety, consult a
qualified electrician if you have questions or encounter problems!
Set-up and start-up
Open the cover of the filter module M2 and insert the unit in the filter module with the pins (1) downward. Ensure that the
braces (2) are correctly seated in the openings of the inner cover (4) and that the pins extend into the rotary handles (3).
Close the cover and connect the unit to the mains. The unit operates automatically. The cleaning intervals are set as
default values.
Over-wintering
Put the system out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Clean thoroughly and check for damage.
Repair
Unit and transformer cannot be repaired. For your own safety, consult a qualified electrician if you detect damage to the