Design Of The Mounting System According To A Certain Number Of Tubes; Example - OEG Heatpipe Installationshandbuch

Röhrenkollektor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
4flex
tube collectors
If the number of tubes cannot be divided by 10 follow the table below for
shortening the mounting rails.
Gross collector
Number
area
of
m
2
tubes
0.14
1
0.28
2
0.42
3
0.56
4
0.7
5
0.84
6
0.98
7
1.12
8
1.26
9
1.4
10
1.54
11
1.68
12
1.82
13
1.96
14
2.1
15
2.24
16
2.38
17
2.52
18
2.66
19
2.8
20
2.94
21
3.68
22
3.22
23
3.36
24
3.5
25
3.64
26
3.78
27
3.92
28
4.06
29
4.2
30
If you want to build a panel with 18 tubes simply take a mounting rail for 20 tubes
and cut it to the size of 1281 mm.
If you want to build a panel with 44 tubes, connect a standard 20-tube mounting rail
with a 30-tube mounting rail and cut the 30-tube mounting rail to the size of 1708 mm.
If you want to mount a collector to a sloping roof, it is important to take the distance
between the rafters into consideration to ensure that you have the required distance
between the roof anchors.
OEG – Solar and storage technology
Type of set
Width of tubes
connected to
each other, mm
71
142
214
285
Mounting rail
356
(10 tubes)
427
712 mm
498
569
640
712
783
854
926
Mounting rail
997
(20 tubes)
1068
1423 mm
1139
1210
1281
1352
1423
1494
1565
1637
Mounting rail
1708
(30 tubes)
1779
2135 mm
1850
1921
1992
2063
2135
35
Design of the mounting
system according to a
certain number of tubes

Example