S e r v i c i n g t h e To o l
Regular servicing should be carried out and a comprehensive inspection performed annually or every 500,000 cycles, whichever is
sooner.
The employer is responsible for ensuring that tool maintenance instructions are given to the appropriate personnel.
The operator should not be involved in maintenance or repair of the tool unless properly trained.
D a i l y
Daily, before use or when first putting the tool into service, pour a few drops of clean, light lubricating oil into the air inlet of the tool if
no lubricator is fitted on air supply. If the tool is in continuous use, the air hose should be disconnected from the main air supply and
the tool lubricated every two to three hours.
Check for air leaks. If damaged, hoses and couplings should be replaced by new items.
Check for oil leaks.
If there is no filter on the pressure regulator, bleed the air line to clear it of accumulated dirt or water before connecting air hose to
tool. If a filter is fitted, drain it.
Check that the nose equipment is correct.
Ensure Deflector 52 is fitted to the tool.
Check that the stroke of the tool meets the minimum specification (page 5). It is the distance travelled by the chuck collet with nose
equipment fitted, measured before trigger is pressed and when trigger is fully depressed.
We e k l y
Check for air leaks on air supply hose and fittings.
Dismantle and clean nose assembly, with special attention to jaws (lubricate with Moly Lithium grease EP 3753 before refitting).
Lubricate cam faces and bearing faces on collar splitters with Moly Lithium grease EP 3753.
M o l y L i t h i u m G r e a s e E P 3 7 5 3 S a f e t y D a t a
Grease can be ordered as a single item, the part number is shown in the Service Kit page 14.
First Aid
SKIN:
As the grease is completely water resistant it is best removed with an approved emulsifying skin cleaner.
INGESTION:
Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk.
EYES:
Irritant but not harmful. Irrigate with water and seek medical attention.
Fire
FLASH POINT: Above 220°C.
Not classified as flammable.
Suitable extinguishing media: CO
Environment
Scrape up for burning or disposal on approved site.
Handling
Use barrier cream or oil resistant gloves.
Storage
Away from heat and oxidising agent.
I M P O R T A N T
,
Halon or water spray if applied by an experienced operator.
2
Item numbers in bold refer to the General Assembly drawings and Parts List pages 18-19.