P u t t i n g i n t o S e r v i c e
A i r S u p p l y
All tools are operated with compressed air at an optimum pressure of 5.4 bar. We recommend the use of pressure regulators and
automatic oiling/filtering systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to
ensure maximum tool life and minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced in the system
or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured
where operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres
1
or
/
".
4
Read daily servicing details page 13.
O p e r a t i n g P ro c e d u r e
Ensure that the correct nose assembly is fitted.
Connect the tool to the air supply.
®
Push the Avdelok
pin through the application hole .
Place the collar on the pin (orientation as shown right).
Keeping the head of the pin against the application, push the tool
onto the protruding pin tail.
Fully depress the trigger. One cycle will ensure that the collar is
swaged into the lock grooves of the pin and the the pin breaks at the
breaker groove.
Release the trigger. The tool completes its cycle by pushing itself off
the collar and ejecting the pin tail at the rear.
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR
OR LUBRICATION UNITS)
8
LUBRICATOR
PRESSURE REGULATOR
AND FILTER
(DRAIN DAILY)
TAKE OFF POINT
FROM MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
7