Level Adjustment
• For easy reference, position the leg base in such a way that
the circular bubble is above one of the adjustable legs.
• The circular bubble should be centered in the vial.
• If adjustment is required, proceed as follows
(See Figure
) :
F
• Turn the rear adjustable legs to bring the circular
bubble to the edge of the vial as indicated.
• Center the circular bubble by turning the front
adjustable leg.
Operation
NOTE:
• See LED Descriptions for indications during operation.
• Before operating the laser tool always be sure to check the
laser tool for accuracy.
• In Manual Mode, Self-Levelling is OFF. The accuracy of the
beam is not guaranteed to be level.
• Laser tool will indicate when it is out of compensation
range. Reference LED Descriptions. Reposition laser tool
to be closer to level.
• When not in use, please be sure to power OFF the laser
tool and place the pendulum lock in the locked position.
Power
• Press
to turn laser tool ON.
• To turn laser tool OFF, repeatedly press
OFF mode is selected OR press and hold
seconds to turn laser tool OFF while in any mode.
Mode
• Press
repeatedly to cycle through the available
modes.
Self-Levelling / Manual Mode (See Figure
• The pendulum lock on the laser tool needs to be
switched to the unlocked position to enable self-
levelling.
• The laser tool can be used with the pendulum lock in
the locked position when it is required to position the
laser tool at various angles to project non-level / plumb
straight lines or points.
77-322
Pulse Mode (See Figure
• When laser tool is ON, press
pulse mode.
• Pulse mode allows use with laser detector.
Applications
Plumb / Point Transfer
• Using the vertical laser beam, establish a vertical reference
plane.
• Position the desired object(s) until they are aligned with the
vertical reference plane to ensure object(s) are plumb.
• Establish 2 reference points that need to be plumb.
• Align either the down laser beam or the up laser cross to a
set reference point.
• The opposing laser beam(s) will be projecting a point which
is plumb.
• Position the desired object until the laser beam is aligned
with the second reference point that needs to be plumb
with the set reference point.
Level / Point Transfer
• Using the horizontal laser beam, establish a horizontal
reference plane.
• Position the desired object(s) until they are aligned with the
horizontal reference plane to ensure object(s) are level.
until the
Square
for ≥ 3
• Using either of the vertical laser beams that cross the
horizontal laser beams, establish a point where the 2
beams cross.
• Position the desired object(s) until they are aligned with
both the vertical and horizontal laser beams to ensure
object(s) are square.
Pulse Mode
)
H
• Setting laser tool to pulse mode allows use with optional
laser detectors.

Manual Mode

• Disables self-levelling function and allows laser unit to
project a rigid laser beam in any orientation.
)
J
to turn ON / OFF
(See Figure
)
J
(See Figure
)
H