Herunterladen Diese Seite drucken

HELIOSA HI DESIGN 11B20 Gebrauchsanweisung Seite 12

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

4. TECHNICAL DATAS HELIOSA® HI DESIGN 11
* HEATED AREAS
The heated areas can vary according to the installation height, the environmental conditions and the synergy produced when
several heaters installed. In the latter case results can be significantly higher.
5. INSTALLATION TO WALL (see page 32) - cod. 11B20 / 11FM20
Install the heater on the wall at a minimum distance of 20 cm from the ceiling. (see installation examples). The height at which the
heaters are normally installed varies from 2.0 metres to a maximum of 2.3 m. Wall mounting is the ideal solution to achieve the
best results in terms of heat with the reflector at a 45° angle and the heater perfectly horizontal. The appliance must not be placed
immediately below a mains socket.
6. INSTALLATION UNDER A PARASOL (see page 33) – cod. 11BX5
1. Do not close the parasol until the heater has been switched off and has cooled down.
2. If the heater is removed from the parasol, use a water tight plug for the connection.
3. If the heater is left on the parasol, make sure that it is mounted so that the heater's shield cannot come into contact with the
canvas of the parasol; this will avoid damage.
7. INSTALLATION IN THE BATHROOM
The fixed installation of HELIOSA® HI DESIGN 11, inside a bathroom, must be made in a way that switches and controls cannot be
touched by those who are under the shower or inside the bath.
8. POSITIONING OF HELIOSA® HI DESIGN 11
1. Aim the HELIOSA® HI DESIGN 11 reflector in the direction required for the wall-mounted installation. The normal angle is 45° to
the horizontal plane.
2. Never install HELIOSA® HI DESIGN 11 on an inflammable surface or facing an inflammable surface.
3. HELIOSA® HI DESIGN 11 must be placed at a clear distance (line of vision) of not less than 2.0 metres from objects such as
cardboard, fabrics, curtains and windows. If used in workshops and garages where there are inflammable paints, HELIOSA® HI
DESIGN 11 must be located more than 4 metres away from the hazard.
4. We recommend that the heater HELIOSA® HI DESIGN 11 is not used in dusty non-ventilated environments to avoid damage to the
bulb.
5. If used outdoors HELIOSA® HI DESIGN 11 IP 20 (cod.11B20-11FM20) should be installed in a place sheltered from rain.
9. WIRE GUARD
a) The wire guard should be used if protection is required (for example sports halls or places where games are played). In areas
where indoor football is played, it may be necessary to fit additional external guarding to cope with the force of impact.
b) The wire guard is simply clipped over the front of the reflector.
c) The wire guard must be installed when the heater is fixed under a height of 2,5 m from the floor level and this assembly must be
done during installation and by a qualified electrician.
d) The HELIOSA® HI DESIGN 11 protective wire guard has been designed to prevent direct access to the heating elements and must
not be removed while the heater is being used.
e) The wire guard does not guarantee full protection for children or the disabled.
11

Werbung

loading

Diese Anleitung auch für:

11fm2011bx5