Verfügbare Sprachen

7 Protective circuits

Protective circuits are provided to prevent
damage to the speakers and the amplifier .
When the limit level is reached at the out-
put, the integrated level limiter will reduce
the input signal . In case of overload of the
amplifier, this will prevent distortions which
may damage the speakers .
An additional protective circuit will sep-
arate the speaker from the output of the
corresponding channel . When this circuit is
activated, the corresponding red PROTECT
LED (1) will light up .
1 . briefly after switching on (switch-on delay)
2 . in case of overload, overheating or failure
The amplifier channel will automatically
resume operation when the amplifier has
cooled down .
Switch off the amplifier and make sure to
eliminate the cause of failure if
1 . a PROTECT LED still lights up after switch-
ing on .
2 . a PROTECT LED lights up during operation
and still lights up when the amplifier has
cooled down .
3 . the circuit breaker (14) of model STA-
1500A has tripped . When the amplifier
has been switched off, press the button to
reset the circuit breaker, if required .
8 Specifications
Model
Power rating
RMS output power
Stereo at 4 Ω
Stereo at 8 Ω
Bridge mode at 8 Ω
Input sensitivity
Input impedance
Frequency range
THD
Crosstalk attenuation
S / N ratio
Connections
Line signals
Speakers
Ventilation
Ambient temperature
Power supply
Max . power consumption
Dimensions (W × H × D)
Rack spaces
Weight
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
STA-900A
900 W
2 × 450 W
2 × 330 W
1 × 900 W
1 V
10 kΩ
20 Hz – 20 kHz
< 0 .1 %
> 60 dB
> 84 dB
XLR, 3 poles, bal .
NEUTRIK Speakon
2 temperature-controlled fans
0 – 40 °C
230 V/ 50 Hz
1850 VA
482 × 88 × 430 mm
2 RS
13 kg
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
STA-1500A
1500 W
2 × 700 W
2 × 550 W
1 × 1500 W
1 V
10 kΩ
20 Hz – 20 kHz
< 0 .1 %
> 60 dB
> 77 dB
XLR, 3 poles, bal .
NEUTRIK Speakon
2 temperature-controlled fans
0 – 40 °C
230 V/ 50 Hz
2725 VA
482 × 88 × 430 mm
2 RS
15 .5 kg
Subject to technical modification .