 Measures should be taken to exclude any danger
from electricity (e.g. by complying with the local reg-
ulations on electrical equipment). If work is carried
out on live electrical components, they should be
unplugged from the mains or the main switch turned
off and fuse unscrewed. A motor protection switch is
to be provided.
 Basically, all work on the pump or pump unit should
only be carried out when the pump is stationary and
not under pressure. All parts must be allowed to re-
turn to ambient temperature. Make sure that no-one
can start the motor during such word. It is essential
that the procedure for stopping the system de-
scribed in the Operating Instructions is observed.
Pumps or pump systems that carry media that are
dangerous to health must be decontaminated before
being taken apart. Safety Data Sheets for the vari-
ous liquids handled. Immediately the work has been
completed, all safety and protective devices must be
replaced or restarted.
 Under EC machinery Directives, every machine
must be fitted with one or more emergency com-
mand devices by which situations which represent
an immediate danger or which could later be dan-
gerous can be avoided.
 If the emergency command device is no longer op-
erated after an emergency "off" switch has been
triggered, this must be maintained by blocking the
emergency command device until it is released
again. It should not be possible to block the device
without this triggering an emergency "of" switch. It
should only be possible to release the device
through an appropriate action; this release should
not start the machine up again – it should only make
it possible to start it up again.
 If the power supply is interrupted or restored after
being interrupted or if it is changed in any other way,
this should not cause any danger (e.g. start up with-
out control or unexpected, pressure hammer).

2. Applications and Technical Description

2.1. Applications

XYLEM disposal units SEKAMATIK 10E 5M are used for
pumping waste water from rooms which are below the sew-
er level.
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be
checked.

2.2. Product description

Odour-tight and watertight complete lifting station with one
pump. The lifting station consists of a collecting tank with
three DN 40 hose with integrated non return valve for the
connection of inlet pipe (two hoses on the side and one
hose at the top of the tank),a revolving discharge pipe DN
25 (also with integrated non return valve) and air vent.

2.3. Technical Data

Discharge
Supply Voltage
Motorpower P
1
Motorpower P
2
Nominal current
Enclosure class (complete unit)
Insulation class
Speed
Total head
Flow
Cable
Weight
2.4. Operating Conditions
Maximum liquid temperature: 35°C, short term up to
60°C.
Operation: The motors are designed for intermittent opera-
tion (S3) 3 / 7 min. (3 min. operation, 7 min. break). The
integrated thermal switch protects the motor from overheat-
ing by cutting of the supply to the pump.
This unit is not admitted for use of condensate!

2.5. Explosive Environments

This unit is not admitted for use in explosive environ-
ments.

3. Warranty

Our warranty only covers pumps which are installed and
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and
being used for the applications mentioned in these in-
structions.

4. Transport and Storage

Never use the cable or the pressure hose to lift, lower
or transport the unit.
The unit may be transported and stored in vertical or
horizontal position. Make sure that it cannot roll or fall over.
For longer periods of storage, the unit should be protected
against moisture, frost or heat.

5. Electrical Connection

Before operation, an expert check must secure that the
required electrical protection measures exist. The connec-
tion to ground, earthing, isolating transformer, fault current
breaker or fault voltages circuit must correspond to the
guidelines set forth by the responsible power plant.
The voltage required in the technical data sheet
must correspond to the existing line voltage.
Make sure that the electrical pin-and-socket connec-
tions are installed flood- and moisture-safe. Before starting
operation check the cable against damages.
The end of the pump power supply cable must not be
submerged in order to prevent water from penetrating
through the cable into the motor.
The electrical connection of the pump should be carried out
in accordance with local requirements and regulations.
The operating voltage and frequency are marked on the
pump and controller nameplates. Voltage tolerance: +6%
11
1" (DN 25)
230V/ 1Ph, 50Hz
650 W
350 W
2,1 A
IP 44
B
2900 rpm.
6,5 m
72 l/min.
1,1 m with plug
8,0 kg