Maintenance
(the motor must be stopped)
Before carrying out any operation disconnect
the machine from the mains
• Clean the machine daily.
• The tables can be removed for ease of cleaning
(See fig.  4c).
- Tilt the motor to the bevelling position.
- Grip the large table 14a on both sides.
- Pull the safety latch 27.
- Lift the tables by pushing the assembly halfway
along their travel and lifting the large table to
remove it from the blocking point before the port.
Pull the assembly and remove the small table's rear
support 14b. Remove the tables.
- To re-insert the tables, position the small table's rear
support in its port and fold the assembly until the
large table's front support can be lowered when its
port is open.
Fully free the motor (in bevel position) to
!
remove and replace the tables. Do not put your
hands between the two tables.
• Empty regularly the tank to remove muddy deposits
which could clog the pump and thus cause premature
wear.
• Wash the tray with plenty of water.
• Clean the pump.
• Store in a dry place
• Clean the rails with particular attention: we advocate
the use of a slide polish, type Loctite VG 26.
Store in a dry place, not accessible to children.
!
Maintain the tools carefully.
18
- English
Operator's manual - TS 100 R

Fault finding

In the event of faulty operation refer to the tables below to
find a solution.
The machine does not work
Causes
Not plugged in properly or
cable damaged
No mains voltage
Switch defective, motor
cable damaged
Motor faulty (no power,
unpleasant smell)
Difficult starting
Causes
Single phase motor starting
condenser
Three-phase supply not
correct (on 2 phases, motor
cable faulty)
The pump does not start
Causes
The mains lead is not
correctly connected or is
damaged
No voltage in pump circuit
or mains supply circuit
The pump does not pump water
Causes
An air bubble may have
formed inside the pump
body
The turbine is jammed
Remedies
Make sure that the supply is
correctly plugged in (plug,
extension lead, etc)
Check the supply cable
Test or have tested by an
electrician (circuit breaker,
plug, etc)
Have tested by an electri-
cian or contact the service
department
Contact the service depart-
ment to have the motor
replaced
Remedies
Replace the condenser
Have it checked by an elec-
trician or contact the service
department
Remedies
Check the mains lead
Check the pump circuit and
mains supply circuit
Remedies
Holding the pump of the
outlet pipe remove it from
the water and reimmerse it
Unscrew the filter and, using
a small screwdriver, remove
all dirt from the operating
area of the turbine.