12
Error message
If an error should occur on the heater or other equipment (control panel, temperature sensor etc.) an
error message will be shown using LED indicators. The indicator LEDs will fl ash whilst one LED on the
1-10 scale is continuously lit or fl ashes. If it lights continuously, it refers to error message 1-10 and if it
fl ashes, it refers to error messages 11-20.
Error messages ( – indicates not relevant to this application):
1.
Temperature sensor not connected or faulty
2.
-
3.
Heater circuit board overheated
4.
-
5.
-
6.
Contact between heater and control panel lost
7.
Contact with temperature/humidity sensor lost
8.
-
9.
Communication with timer lost
10. Current to timer disrupted
11. -
12. -
13. Humidity sensor faulty
14. Temp. sensor faulty
15. Communication problem with heater
16. Temperature cut-out activated and must be reset
17. Too many humidity sensors connected
18. Too many temperature sensors connected
19. Door has been open for more than 5 minutes when the sauna is on.
20. Door opened more than 60 seconds since the last shut-down or delayed start activated, and door
opened more than 60 seconds after activation.
For certain errors, disconnecting current to the heater for a brief period and then reconnecting can be
tried. This mostly concerns problems that have occurred with communication between units connected.
In the event of error number 3, the heater will be automatically switched off. When the temperature has
dropped approx. 20°C, the sauna heater can be restarted. Always investigate why the heater overhea-
ted. It can be the result of insuffi cient ventilation or that the heater needs crumbled stone removed.
Contact your dealer for other errors or if an error cannot be corrected according to the above. Check the
heater's type plate and note the type, serial number, year of manufacture and make a note of any error
code on the control panel before contacting Tylö Customer Support.