10
How to program:
1.
Connect the control panel to the heater. Wait until contact between them is established. Once
started, programming must be started within 5 minutes.
2.
Press the left arrow. The ON diode (C) will start to fl ash. After 5 seconds, it will be lit continuously.
Release the button.
3.
Press the right arrow. The node diodes will start to fl ash (F). After 5 seconds, they will light conti-
nuously and the program selection diode will light (D). Release the button.
4.
Scroll to the program required and confi rm with ON.
5.
Restarting the system.
6.
The active program diode will fl ash 4 times when starting.
If changing the program later, disconnect the control panel to perform the above procedure within 5
minutes of restart.
Start
To start the sauna, press (C). The last temperature setting and operating time will be used. The symbol
will light in the indicator fi eld to show that the heater has started.
To switch off the sauna before the end of the operating time set, press the same button again.
Setting temperature
Use the function selection buttons (F) to select temperature setting. Use the - and + buttons to then
select temperature setting 1-10. The temperature obtained depends on the max. temperature set, i.e.
which program has been set. Temperature can be adjusted whilst taking a sauna if required.
Max. temperature
55 °C
20
90 °C
30
110 °C
65
Once the temperature has been set and the heater started, the set temperature will be indicated con-
tinuously and actual temperature will be indicated by a fl ashing indicator. Once the actual temperature
reaches the set value, the fl ashing will stop.
Setting delayed start
You can set a time when the heater is to start after a certain time. A door contact must be connected for
this purpose (see "Connecting door contact and its function"). Use the function selection buttons (F) to
select the timer symbol. Use the – and + buttons to select the number of hours until the heater is to start
(1-10 hours). Activate delayed start by pressing the Start button (C).
The indicator symbol for delayed start will light (fi eld B) and the time delay diode will start to fl ash. The
fl ashing indicator will count down and show the actual time remaining until the heater starts. Once the
heater starts, the panel will switch to showing set temperature automatically.
The door contact to be used is Tylö item number 90908035.
Set temperature (approx. value, °C)
1
2
3
24
28
37
43
70
75
4
5
6
32
36
39
50
57
63
80
85
90
7
8
9
43
47
51
70
77
83
95
100
105
10
55
90
110