Error Codes - techem classic S3 (MID) Betriebsanleitung

Rechenwerk
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Displays/operation
It is possible to step through the individual displays by pressing the push-button. In doing
so, a distinction is made between short and long presses of the button.
Briefly pressing the button (< 3 seconds) allows the user to step through the display
within a loop.
With a long button press (> 3 seconds), the display steps through into its next loop.

Error codes

If an error occurs, the error code is shown in the main loop. All the other windows conti-
nue to be available by pressing the button.
Code
Description
C-1
Fundamental parameter in flash memory or RAM destroyed
E-1
Faulty temperature measurement:
- Temperature range outside (-19.9 °C...189,9°C)
- Sensor short circuit
- Sensor break
E-3
Sensors in hot and cold branches switched
E-5
Readout too frequent - optical communication momentarily not possible
E-8
Primary power supply failed (only with mains adapter)
- supply via backup battery
E-9
Warning: Battery capacity is running out
Reading out data/ programming
!
Prerequisites:
Techem Bluetooth optical reading head or Diehl metering Bluetooth optical
reading head.
The IZAR@SET software for reading out and configuring the standard functions
The following can be changed with IZAR @SET software on Techem notebooks:
Due date 
m-bus primary address 
12
5
Due date loop 1.1
6
Information loops 3.1 and 4.1