Picture 6, the door seal. A =
metal pin at corner of door
seal
B= hole in door for door
seal pin
(*) The frequency mentioned is a minimum frequency. Local legislation and/or your insurance
prescription might prevail depending on which one is the most stringent. When intensively
using the heater the chimney must be cleaned more frequently.
D.3 MAINTENANCE TASKS
Only provide maintenance to the stove after verifying the stove has inter-
nally and externally cooled down completely!
Never install the unit or operate maintenance to the unit with plugged in
electrical plug. Always make sure the stove is disconnected from mains!
The Zibro authorized installer is fully trained for all maintenance tasks. Therefore
maintenance to the stove must only be done by Zibro authorized installer using
Zibro agreed parts.
G
For maintenance:
• disconnect the chimney and
• disconnect the stove completely from electrical power supply.
D.3.1 Replacing the fire door seal
Take out the fire door seal. Carefully clean the contact area between door and door
seal. Replace the door seal using original Zibro spare part code COM 0244. The door
seal is provided with 4 metal pins at the corners (see picture 6). These pins must care-
fully be pushed inside the holes in the door. Check whether the seal is making a tight
connection all around.
D.3.2 Battery for the clock circuit.
1. Check condition of the battery for the clock every 2 years.
2. Pull the complete clock circuit board from the main circuit board to check the bat-
tery condition. See picture 7.
3. Measure the battery tension with a multimeter. Replace the battery with a soldering
iron when the tension is below 2.8 Volt. See picture 8.
4. Replace the clock circuit board.
Picture 7
D.3.3 Cleaning the fume extraction chamber
The fume extraction chamber needs to be cleaned twice a year by a by Zibro authori-
zed technician.
1. Open the fume chamber using the 2 cylindrical bolts.
2. Clean the chamber using a soft brush and a vacuum cleaner.
Picture 8
4
63