Herunterladen Inhalt Inhalt Diese Seite drucken

Water Connection; Operation - Kärcher HD 6/11-4 M Plus Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HD 6/11-4 M Plus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Water connection

Connection to the water supply
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
 Connect the supply hose (minimum
length 7.5 m, minimum diameter 1") to
the water connection point of the appli-
ance (such as the tap).
Note
The supply hose is not included.
 Open the water supply.
Drawing in water from open reservoirs
 Screw the suction hose (order no.
4.440-270.0) onto the water connec-
tion.
 Connect filter (order-no. 4.730-012.0) to
suction hose.
 Deaerate the appliance:
Unscrew the nozzle.
Switch on the appliance and let it run
until the water exiting is bubble-free.
At the end let the appliance run for ap-
prox. 10 seconds - then switch off. Re-
peat the procedure for a couple of
times.
 Switch off the appliance and fit the noz-
zle again.
22
Danger
Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous areas
(e.g. filling stations) all of the safety provi-
sions and operating instructions detailed in
this manual must be observed.
Warning
Clean engines only at places with corre-
sponding oil separators (environmental
safety).
The jet must not be directed at other per-
sons or directed by the user at him/herself
to clean clothing or footwear.
Risk of blocking. Place the nozzles in the
accessory compartment with their joint
pointing upward.
Only HD 9/19....
Danger
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
Proneness to blood circulation deficien-
cies (cold, numb fingers).
Low ambient temperature. Wear warm
gloves to protect hands.
A firm grip impedes blood circulation.
Continuous operation is worse than an
operation interrupted by pauses.
In case of regular, long-term operation of
the device and in case of repeated occur-
rence of the symptoms (e.g. cold, numb fin-
gers) please consult a physician.
– 4
EN

Operation

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis