Problem
Product runs unevenly or
vibrates strongly
Lawn is not cleanly cut
ß
Error-LED
on the battery
W
is flashing
ß
Error-LED
on the battery lit
W
ß
Error-LED
on the panel lit
W2
Charging control lamp
does not light up
Charging control lamp
flashing rapidly (4 times per
second)
ß
Error-LED
on the charger
E
is flashing
ß
Error-LED
on the charger lit
E
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers
approved by GARDENA.
7. TECHNICAL DATA
Battery Lawnmower
System Battery / smart Battery
Lawn area per battery
charge (up to)
Battery voltage
5041-20.960.02.indb 11
Possible Cause
Blade is damaged or the blade
mounting is released.
Blade is very dirty.
Blade is blunt or damaged.
Cutting height is too low.
Over voltage.
Under voltage.
Battery temperature is out of
range.
Battery error / battery defective.
Blade is blocked.
Motor overload / Controller
temperature is out of range.
(15)
Battery charger or charging cable
are not connected correctly.
(15)
is
Battery temperature is out of
range.
Battery error.
Temperature inside the charger
is too high.
Unit
Value (Art. 9842 / 19090)
m
280
2
V
max. 40 (The maximum
initial no-load voltage of the
battery is 40 V, the nominal
voltage is 36 V)
Remedy
v Have blade tightened or
replaced by an authorised
specialist dealer or the
GARDENA Service.
v Clean the mower (see 4. MAIN-
TENANCE). If this does not
rectify the problem, contact the
GARDENA Service.
v Have blade replaced by the
GARDENA Service.
v Raise the cutting height.
v Remove the battery and
check that the mains voltage
is correct.
v Charge the battery.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Contact the GARDENA service.
v Remove the obstacle.
v Let the controller cool down.
v Connect the battery charger
and charging cable correctly.
v Use the battery in surroundings
where temperatures are
between – 10 °C and 40 °C.
v Remove the battery and
check that you use an original
GARDENA battery.
v Contact the GARDENA service.
Value (Art. 9843 / 19091)
450
max. 40 (The maximum
initial no-load voltage of the
battery is 40 V, the nominal
voltage is 36 V)
11
05.12.16 12:54