Overload protection
thermal overload protection.
Electronic protection:
by forcing it down too hard. When idling and under normal load, the LED is not illuminated.
When excessive force is used, the LED lights up red. If the LED lights up, relieve pressure on
the machine immediately.
If the red warning LED continues to be ignored, the electronic safeguard will shut the machine
off automatically.
After relieving the pressure and power cycling the machine, the machine can be used again
as normal.
Thermal protection:
overloading. If the thermocouple triggers, the machine shuts off automatically and can only
be used again after a cooldown period (approx. 2 min.).
motor coil and the ambient temperature.
Care and maintenance
Always disconnect from mains power before maintenance or repair work!
Although this electrical tool has been designed to require very little maintenance or servicing,
the following points must be borne in mind:
machine shop.