12 Troubleshooting

12.1 Malfunctions

Problem
Valve opens/closes only with
manual opening, but not on any
electric signal
Valve fails to open even with
manual opening
Valve fails to close
Valve fails to close completely
(only at valve-in-head
sprinklers)
Rotary speed too low / too high
or does not rotate at all
Output pressure at sprinkler
nozzle too low or casting range
too short
(only at valve-in-head
sprinklers)
Subject to change without prior notice.
TDP062d+e.doc
Perrot REGNERBAU CALW GmbH
Cause
Screw for 'Manual opening'
is set to OFF
Core is jammed in the coil
No / inadequate power supply Establish 24V AC power supply
Coil defective
Overflow channel from coil
clogged
Control water hole or relief
hole clogged
Feeder pipeline under no /
insufficient pressure
Coil seat dirty
Bits of dirt between valve seat
and sealing plate
Diaphragm defective
Insufficient drop in pressure at
the valve
Control water filter dirty
Screw for ‚Manual opening' is
not tightened
Bits of dirt between valve seat
and sealing plate
Pressure regulating insert
damaged
O-ring at coarse filter
damaged
Inlet nozzle incorrectly set
(see chapter 7)
Turbine blocked by stones or
bits of dirt
Inlet nozzle or filter have
worked loose
Stones and bits of dirt are
hindering an unimpeded flow-
through of water
Pressure regulator in minus (-
) position
Rev. 27.06.2013
Industriestraße 19-29 / D-75382 Althengstett / Germany
Telefon : +49-7051-162-0 / Fax : +49-7051-162–133
E-mail : perrot@perrot.de / E-mail Konstruktion : technik@perrot.de
Remedy
Turn screw to the left as far as
it will go
Take out coil and clean core
Check coil resistance (should
be ca. 35 ohms) and replace if
necessary
Clean channel
Clean control water / relief
hole
Establish pressure supply
Clean coil seat
Clean valve seat and sealing
plate
Take out valve and replace
diaphragm
Tighten 'pressure regulator
screw'
Clean control water filter
Tighten Screw for ‚Manual
opening'
Clean valve seat and sealing
plate
Exchange pressure regulating
insert
Exchange O-ring and seal with
teflon tape
Set inlet nozzle to correct
nozzle diameter
Clean turbine
Clip parts together again
Clean valve and flush sprinkler
Turn pressure regulator screw
to the left towards (+)