8
Valve insert removal / installation
Ensure sprinkler is not under pressure.
Using a big screwdriver, unclip the lid
Using a screwdriver, remove white retaining ring
Hollow screw
Pull sprinkler insert out of the housing
8.1
Taking out the valve
Take off retaining ring by help of retaining ring lifter (see chapter 4).
Screw valve lifter / coarse filter wrench onto valve insert's studs and manually tighten.
Pull out valve insert complete with valve lifter and unscrew. Valve insert is now held
on hollow screw by O-ring only.
TDP062d+e.doc
Perrot REGNERBAU CALW GmbH
Retaining ring
Retaining ring
Rev. 27.06.2013
Industriestraße 19-29 / D-75382 Althengstett / Germany
Telefon : +49-7051-162-0 / Fax : +49-7051-162–133
E-mail : perrot@perrot.de / E-mail Konstruktion : technik@perrot.de