Operating mode „Switch-off delay with resetting"
VCC
Set
GND
The function switches the relay when the input signal is activated (when the button „Set" is
pushed). When the input signal is deactivated, the relay is deactivated with a time delay.
The minimum/maximum switching time of 10 s.....30 min can be set by potentiometer R3
(rotating area 0....98%).
The deactivation delay is restarted when the input „SET" is activated during current deactivation
delay (at the top of the figure when pushing the button „Set").
Example for a signal process (configuration at the device, reset inputs wired); „SET" =
activation via input signal, „RELAY" = switching duration of the relay, „T1" = time of deactivation
delay (setting the rotating potentiometer R3):
SET
RELAIS
|<----------T1---------->|
Operating mode „power surge switch (on/off switch)"
If the button at the input „SET" is pushed, this causes the relay to toggle. Resetting always
cancels.
This function is activated in the delivery condition when the potentiometer is set to >=98% (the
status LED flashes). This basic setting is overwritten when transferring other functions by PC
software.
Example for a signal process („SET" = activation via input signal, „RELAY" = switching duration
of the relay, „RESET" = resetting via input „RESET"):
SET
RESET
RELAIS
Operating mode „Staircase light with warning and time reset"
VCC
Set
GND
The function is selected when the „RESET" input remains unwired.
The minimum/maximum switching time of 10 s.....30 min can be set by potentiometer R3
(rotating area 0....98%).
If the button „Set" is pushed, the relay switches. When releasing, the deactivation delay T1
starts, followed by a 30-second warning phase T2 (repeated short deactivation before the
output is permanently deactivated).
Repeated pushing of the button during the function or warning phase leads to restarting (start
of the deactivation delay T1 with subsequent warning phase T2).
SET
RELAIS
|<--------------------T1------------------->||<----------------------------T2------------------------->|
SET
RELAIS
|<-------------------T1------------------->||<--------------------------T2------------------------>|
PC Configuration
The software and the associated operation instructions are available free of charge
on our website www.conrad.com in the download area for the multifunction timer (item
no. 393903 or 393904). A matching interface cable is required for confirmation
(Conrad item no. 197339).
J1
1
VCC
2
GND
3
SET
4
SET
5
RESET
6
RESET
7
SEQ
|<----------T1---------->|
|<----------T1---------->|
J1
1
VCC
2
GND
3
SET
4
SET
5
RESET
6
RESET
7
SEQ
0,3 s
0,3 s
0,3 s
0,3 s
|<------------T1-------
Overview of the functions for configuration via the PC-software:
• Functions with relay output
Switch-on delay
Switch-off delay (resettable / not resettable)
Activation/deactivation delay (resettable / not resettable)
SET => On, RESET => Off
Power surge switch
On-off change (permanent / number of repetitions can be set)
Presence simulation (randomly controlled)
• Functions with relay and sequence output
Alternating button (REL<->SEQ)
Alternating button (REL->SEQ->OFF)
Step button (REL->REL+SEQ->OFF)
Step button with switch-off delay
• Logical link of set and reset
Logical operators: AND, OR, XOR
• Staircase light machine
Time Extension
Early shut-down
Short: Extension, long: Switch off
Service mode
Pre-warning option
Disposal
Dispose of the product according to the applicable statutory provisions at the end
of its service life.
Technical Data
Operating voltage ............................... Type „MFT1816-12 V", item no. 393903: 12 V/DC
Power input ......................................... Typically 11 mA (quiescent) or 50 mA (relay active)
Inputs ................................................... 2 x optocoupler inputs „SET" and „RESET" (polarity
Admissible line lengths ....................... Inputs „SET"/„RESET": max. 30 m
Minimum pulse duration ..................... >50 ms
Time until readiness is restored ......... >50 ms
Outputs:
Relay (1xUM) .............................. max. 250 V/AC, max. 16 A, max. 4000 VA
SEQ (Sequence-Out) ................. Open-collector type to connect an external relay, max.
Admissible line length ......................... SEQ.: max. 3 m
Temperature range ............................. -10 °C to +50 °C
Dimensions ......................................... 98 x 22 x 34 mm (L x W x H)
Weight ................................................. 32 g
Accessories
It is not included but must be ordered separately.
0,3 s
• Empty housing:
Type „Wieland 99.800.6046.6", (W x H x D) 27 x 42 x 66 mm, for top-hat rail assembly,
Conrad item no. 524042
• USB-programming cable, Conrad item no. 197339
• Matching relay modules for sequence output:
For multifunction timer „MFT1816-12 V": Conrad item no. 503308
For multifunction timer „MFT1816-24 V": Conrad item no. 503309
Type „MFT1816-24 V", item no. 393904: 24 V/DC
does not have to be observed)
Logical 1 („HIGH"): >3....32 V/DC
Logical 0 („LOW"): 0....1.5 V/DC
max. 24 V/DC, max. 16 A
24 V, 75 mA
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming,
or the capture in electronic data processing systems require the prior written approval by the editor.