Herunterladen Inhalt Inhalt Diese Seite drucken

Beispiele Für Ausgedruckte Berichte; Helix/Bd Test; Vacuum Test - Mocom S CLASSIC 17 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

classic
BEISPIELE FÜR AUSgEDRUCkTE BERICHTE
(mIT OPTIONAlEm DrucKEr)
Ausdruck des Programms (normal)
model
S/N
Ver. SW
counter
0007/0015
Selection
134 °c SOlID
Temperature
134 °c
Pressure
2.10 bar
Process time
4 min
Stand-by
lOW
Pre-vacuum
SINGlE
Drying
FAST
cyclE STArT
01/02/11
12:14
Time
c
----------------------------------------------------------
00:01
cS
079.4
02:02
1PV
093.7
05:48
ET
135.6
06:02
SS
135.9
07:02
135.6
08:02
135.5
09:02
135.4
10:02
SE
135.5
10:37
DS
104.1
11:41
SPD
047.5
16:08
DE
047.6
17:12
cE
084.6
06:32
mAx
136.0
09:59
mIN
135.4
Drying PuIses
01
cyclE END
01/02/11
12:36
STErIlIZATION:
POSITIVE
OPErATOr
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
----------------------------------------------------------
model
S/N
Ver. SW
counter
0007/0015
Selection
134 °c uNIVErSAl
Temperature
134 °c
Pressure
2.10 bar
Process time
4 min
Stand-by
hIGh
Pre-vacuum
FrAcTIONATED
Drying
STANDArD
cyclE STArT
01/02/10
09:52
Time
c
----------------------------------------------------------
00:01
cS
075.1
01:57
1PV
047.S
04:53
1PP
120.5
07:00
2PV
061.1
09:15
2PP
120.4
11:22
3PV
061.1
15:04
ET
135.5
15:19
SS
135.9
16:19
135.4
17:18
135.5
18:19
135.4
19:19
SE
135.5
19:53
DS
104.4
20:57
SPD
048.4
26:55
EPD
094.9
29:15
DE
112.6
29:43
cE
115.8
16:20
mAx
135.9
18:11
mIN
135.4
Drying Pulses
05
cyclE END
01/02/11
10:28
STErIlIZATION:
POSITIVE
OPErATOr
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
----------------------------------------------------------
Ausdruck des Programms

HELIX/BD TEST

model
S/N
Ver. SW
counter
Selection
Temperature
Pressure
Process time
cyclE STArT
Time
----------------------------------------------------------
00:01
cS
bar
02:06
1PV
04:35
1PP
+0.00
05:45
2PV
-0.80
07:02
2PP
+2.15
08:15
3PV
+2.17
11:00
..
+2.14
11:14
..
+2.14
12:14
+2.14
13:14
+2.15
14:14
+0.00
14:45
..
-0.90
15:20
..
-0.84
16:34
...
-0.04
18:21
...
19:21
..
20:06
cE
12:33
mAx
14:44
mIN
Drying pulses
cyclE END
hElIx TEST cOmPlETE
Please attach the indicator hereunder
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
bar
-0.00
-0.80
+1.00
-0.80
+0.98
-0.80
+2.15
+2.17
+2.14
+2.15
+2.14
+2.15
+0.00
-0.90
-0.86
-0.47
-0.04
model
S/N
Ver. SW
0011/0019
counter
hElIx TEST
Selection
134 °c
2.10 bar
3.5 min
cyclE STArT
01/02/11
16:38
Time
c
bar
----------------------------------------------------------
00:00
076.4
+0.00
089.3
-0.89
01:39
120.4
+0.99
062.5
-0.78
6:39
120.2
+0.97
061.1
-0.79
22:39
135.6
+2.15
136.0
+2.17
23:54
135.6
+2.14
135.6
+2.15
cyclE END
135.5
+2.14
135.4
+2.14
111.5
+0.00

VAcuum TEST:

047.8
-0.89
059.5
-0.86
075.4
-0.50
078.7
-0.04
136.0
135.4
01
01/02/11
17:01
OPErATOr
Ausdruck des Programms
VACUUm TEST
0011/0019
VAcuum TEST
01/02/11
11:37
c
bar
cS
035.0
+0.00
E1F
037.4
-0.80
E2F
038.4
-0.79
E3F
042.0
-0.79
cE
045.5
-0.01
01/02/11
12:01
POSITIVE
OPErATOr
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65