Channel assignment information
For the functions, the unit uses eight channels. The first DMX channel is defined with the the OASE
DMX control unit.
Channel
DMX-Channel + 0
DMX-Channel + 1
DMX-Channel + 2
DMX-Channel + 3
DMX-Channel + 4
DMX-Channel + 5
DMX-Channel + 6
DMX-Channel + 7
Please check the master value when you don't see the LEDs shining. The minimum value is at least 1
for the master (DMX-Channel + 4) to see the LEDs shining.
Pos: 165 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 166 /Alle Produkte/Überschriften/H4 Wasserstrahl einstellen @ 13\mod_1255965353543_121.doc @ 79485 @
Setting the water jet
Pos: 167 /Alle Produkte/Warnhinweise/E-ACHTUNG - Netzspannung abschalten @ 13\mod_1259760934607_121.doc @ 84730 @
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Prior to reaching into the water, switch off the mains voltage to all units used in the water.
Switch off the mains voltage prior to carrying out work on the unit.
Pos: 168 /Pumpen/Schlammsauger/Jumping Jet Rainbow Star FT/INB Wasserstrahl einstellen @ 13\mod_1255965056181_121.doc @ 79420 @
1. Undo the Allen screws (36) on both sides of the unit foot (23) using the Allan key (18) and bring the
Jumping Jet Rainbow Star (1) to the desired inclination angle.
2. Retighten the Allan screws (36).
3. Set the pump flow rate.
The flow rate of electrically controlled pumps is set with the control unit (e.g. "In Scenio FM Master
3"), the flow rate of pumps without control feature is set manually by means of a slide in the pump
suction or pressure area.
4. Setting the water jet (Fig. I - K)
Align the jet diaphragm (37) in the hood of the Jumping (1) Jet such that the water jet passes the
centre of the jet diaphragm (37). Ensure that the water jet is not deflected by the water jet diaphragm
(37).
Pos: 169 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
Description
Access of the red LEDs
Access of the green LEDs
Access of the blue LEDs
Not used
Master, Access of the lumination of all RGB
channels
Not used
Strobe
Shutter
Values
0 ... 255, Density of red LEDs
0 ... 255, Density of green LEDs
0 ... 255, Density of blue LEDsc
0 ... 255, Density of all LEDs
0 = Strobe disabled,
255 = Strobe enabled
0 = Shutter closed
255 = Shutter opened