VDV-707 indoor unit for video door phone system
Thank you for purchasing this indoor video station with integral image
memory. This indoor station can be combined with all components from
the VISTADOOR and VISTUS systems. If someone rings at the connected
outdoor station, the indoor station plays the set ring tone and the visitor
can be viewed on the monitor. Two photos are also saved automatically.
You can then talk to the visitor and open the door (if a door opener is
connected).
CONTENTS
Internal unit with 17.8 cm (7") screen size
Fixings
Operating and installation instructions
Drilling template
Key
1 = Microphone
2 = Monitor button
3 = Door opener button
4 = Voice button
GB
5 = LED for muting function
6 = Sleep button
7 = Operating LED
8 = Voice volume adjuster
9 = Bell tone button
10 = Alarm/intercom button
11 = Minus button
12 = Plus button
13 = Menu button
14 = Slot for VTX bell
15 = Volume adjuster for bell tone
16 = Housing screws
17 = Touch-active area
INSTALLATION (Fig. 2a+b)
1. Identify a suitable place to fit the internal unit and lay all the cables
needed to this point.
2. Remove the two screws (16) from the internal unit and lift the front
cover off the unit.
3. There are two attachment clips at the centre of the sides of the
internal unit. Carefully pull off the front cover.
4. For cable entry into the housing, the latter has a hole in it at the
top below the connection terminals.
5. Use a spirit level to correctly align the supplied drilling template
at the point on the wall where the internal unit is to be fitted.
Alternatively, the back of the internal unit housing can be used to
mark the drill holes.
6. Fix the drilling template in position with adhesive tape and drill the
four marked holes (Ø 6 mm).
7. Take the drilling template off and insert one of the plugs supplied
in each of the holes.
8. Feed the connecting cable through the hole in the bottom of the
internal unit housing and screw the housing to the wall using the
four screws.
9. Connect the cables as shown in the wiring diagram (Fig. 4).
NOTE: Do not cut the cables too short. There are clips in the bottom of
the housing that the cable can be wound around.
10. Attach the front cover with the monitor. Make sure that the
attachment clips engage properly.
NOTE: Also make sure that any bare wires do not touch the PCB
shielding; ideally the wires should be as short as possible.
11. Screw the front cover back on using the two screws (16).
STARTUP
Connecting the power supply
The power supply can be connected to the internal or external unit, as
preferred.
The power supply can also be fed in at a star point, if all the signal
cables have been laid from the fuse box to the external and internal
units, for instance. The power supply unit should then be connected in
parallel to ground/GND and +15 V.
Once all the components have been fitted and connected, switch on
the operating voltage. Depending on the type of installation, either
plug the mains adapter into a suitable socket or switch on the circuit
breaker that is connected to the DIN rail power supply unit. Ring the
external unit once to initialise the system (if multiple external units are
installed, each external unit must be rung once).
NOTE: Switch the operating voltage off again before carrying out any
work on the system!