The plug has to be fitted in a proper socket. If
connecting the appliance directly to the elec-
tric system, it is necessary that you install a
double pole switch between the appliance
and the electricity supply, with a minimum gap
of 3 mm between the switch contacts. The dou-
ble pole has to be of a type suitable for the
required load in compliance with the current
rules.
The connection cable has to be placed in order
that, in each part, it cannot reach a 90 °C tem-
perature. The blue neutral cable must be con-
nected to the terminal block marked with "N".
The brown (or black) phase cable (fitted in the
terminal block contact marked with "L") must
always be connected to the live phase.
Replacement of the connection cable.
If the connection cable must be replaced, only
a type H05V2V2-F T90 cable must be used.
The cable section must be suitable to the volt-
age and the working temperature. The yel-
low/green earth wire must be approximately
2 cm. longer than the brown (or black) phase
wire.
To open the terminal block and reach
the terminals, proceed as follows:
1. insert the point of a screwdriver into one of
the two visible protruding part of the ter-
minal block
2. exert a light pressure and lift
The hob is supplied with a three pole terminal
block designed for a 230 V connection. The
yellow/green earth wire must always be con-
nected to the terminal marked with the symbol
.
Upon completion, secure the connection cable
with the cable clamp and close the terminal
block.
A duplicate rating plate is supplied with
this appliance. For a fast identification af-
ter installation, please stick it directly on the
user manual booklet after Technical data
chapter close to the rating plate drawing.