Installation instructions

Safety precautions

Read and store these instructions carefully. Safe use can only
be guaranteed if the appliance has been installed by a
professional and in accordance with these assembly
instructions.
The appliance must be connected to the mains only by a
licensed and trained technician.
If you wish to convert to a different type of gas, call the after-
sales service.
: Risk of gas escape!
After connecting the appliance to the gas supply, always check
the connection for leak tightness. The manufacturer accepts no
responsibility for the escape of gas from a gas connection
which has been previously tampered with.
The fitter or the installer is liable for damage or faults resulting
from incorrect assembly or installation.
When installing the appliance you must observe the building
regulations that are currently applicable and the regulations set
by the local electricity and gas suppliers (e.g. Germany: DVGW-
TRGI/TRGF; Austria: ÖVGW-TR).
Switch off the power and gas supply before carrying out any
work.
The information on the rating plate regarding voltage, gas type
and gas pressure must comply with the local connection
conditions.
Electrical appliances must always be earthed.
If an extractor hood is to be fitted, it must be fitted according to
the associated assembly instructions. Take into consideration
the specified minimum distance to the hob.
This appliance must not be installed on boats or in vehicles.

Before installing

These instructions are intended for several models. Details may
vary, depending on the appliance model.
Read the following information about the appliance and the
guidelines for ventilation.
In this section, you will find information on
Unpacking
the appliance classes
the appliance dimensions
the distance from any adjacent furniture
the rating plate
Unpacking
Check the appliance for damage after unpacking it. Do not
connect the appliance if it has been damaged in transport.
Dispose of packaging in an environmentally-friendly manner.
Appliance classes - Fig. 1
This appliance corresponds to the following appliance classes:
Appliance class
Fig. 1a
Fig. 1b
Appliance dimensions - Fig. 2
Adjacent units - Fig. 3
Adjacent units and adjacent unit fronts must be heat-resistant up
to at least 90 °C. If the appliance is installed close to other
kitchen units, you must comply with the minimum distances
specified in the diagram.
Description
Class 1
Non flush-fitted cooker
Class 2 - subclass 1
Cooker immediately adjacent to two units, con-
sisting of a single unit, can also be installed so
that the side walls are accessible
Rating plate
The technical data for the appliance can be found on the rating
plate.
The rating plate is located on the inside of the storage
compartment flap.
The setting values are specified on a label on the appliance
packaging.
Enter the product number (E no.), production number (FD no.),
factory settings for the type of gas/gas pressure and, if
applicable, the converted gas type into the table below. The
changes made to the appliance and the type of connection are
crucial for the safe and correct operation of the appliance.
E no.
O
After-sales service
Type of gas/gas pressure
Factory setting
Type of gas/gas pressure
Conversion
Guidelines for ventilation
This appliance must only be installed in a room that is
sufficiently ventilated.
If the total power for all gas appliances is below 11 kW, then this
requirement is met if the installation room has a volume of over
15 m³ and at least one door leading outside or one window that
can be opened.
If the total power for all gas appliances is above 11 kW, then
this requirement is met if the installation room has a volume of
over 2 m³ per kW and at least one door leading outside or one
window that can be opened. Furthermore, an exhaust extractor
hood or a controlled domestic ventilation system (no
recirculated air operation) should be present and should have a
minimum flow volume of 15 m³/h for each kW of total power for
all gas appliances. Appropriate supply air openings must be
present.
Note: In some countries, the requirements for minimum room
volume vary. Find out information on this from your after-sales
service.

Installation

This appliance is supplied with a set of adjustable feet and a
glass cover. The glass cover is prefitted.
Fitting the adjustable feet - Fig. 4
Remove all parts that are not permanently fixed, especially the
1.
pan supports and burners.
Remove the accessories from the oven.
2.
Tilt the appliance by raising it slightly on one side from the floor.
3.
Screw the adjustable feet into the mounting holes on the
4.
underside of the appliance.
Note: If you then need to pull the appliance, screw in the
adjustable feet fully.
Only finally level the appliance when the electricity and gas
5.
have been connected, and all of the installation work has been
completed.
Fitting the splash guard - Fig. 5
Remove the packaging and the protective film from the splash
1.
guard.
Loosen the two screws on the back of the appliance.
2.
The nuts are no longer required.
Place the splash guard into the holes intended for this purpose
3.
using the dowels.
Insert and tighten the bolts from below.
4.
FD no.